![Dini Argeo 3590 EBOX Series Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/dini-argeo/3590-ebox-series/3590-ebox-series_technical-manual_2505688069.webp)
3590EKR, 3590EXP, 3590EXT, 3590 EBOX, CPWE, CPWET series indicator E-AF03_05.01_14.07_EN_T.doc
69
COMMANDS
Version reading:
[CC]VER<CR LF>
Instrument’s answer:
[CC]VER,vvv,E-AF03
b
<CR LF>
in which:
vvv is the firmware version
Data reading:
[CC]READ<CR LF>
or:
[CC]R<CR LF>
Instrument’s answer:
see section 5.4.
Semiautomatic tare:
[CC]TARE<CR LF>
or:
[CC]T<CR LF>
Preset tare:
[CC]TMANTTTTTT<CR LF>
or:
[CC]WTTTTTT<CR LF>
(short command)
in which:
W= command
TTTTTT = tare in ASCII, max 6 characters
Example: W10.0 <CR LF>
Zero:
[CC]ZERO<CR LF>
or:
[CC]Z<CR LF>
Clear:
[CC]CLEAR<CR LF>
or:
[CC]C<CR LF>
Reading of extended weight string: [CC]REXT<CR LF>
Instrument’s answer:
[CC]B,hh,NNNNNNNNNN,YYTTTTTTTTTT,PPPPPPPPPP,MMMMMMMMMM,uu<CR LF>
in which:
[CC] = INSTRUMENT CODE IN THE FORMAT OF TWO ASCII DECIMAL DIGITS
ONLY WHEN THE 485 PROTOCOL IS SELECTED (FOR EXAMPLE 00)
hh =
UL
Underload
OL
Overload
ST
Stability of the display
US
Instability of the display
B =
scale number (zero for the remote scale)
NNNNNNNNNN =
net weight on 10 characters including sign and decimal point
YY =
"PT" if the tare weight is entered with the keyboard, otherwise YY = " " (two space characters) if
the tare weight is weighed
TTTTTTTTTT =
tare weight on 10 characters including sign and decimal point
PPPPPPPPPP =
always 0
MMMMMMMMMM = always 0
uu = Unit of measure "Kg" "
b
g" "
b
t" "lb
CR = Carriage Return (ascii character decimal code 13)
LF = Line Feed (ascii character decimal code 10)
NOTE
: With
remote scale
in error only with AF0X or ALIBI protocol in the place of the UL/OL/ST/US heading flags it will
put ER; this is valid for all the weight reading commands which contain the status flags; for example: READ /R
/RALL /REXT.
Net/Gross change:
[CC]NTGS<CR LF>
Instrument’s answer:
[CC]OK<CR LF> if the command NTGS has been RECEIVED.
[CC]ERR04<CR LF> if the entire command is wrong.
Print:
[CC]PRNT<CR LF>
or:
[CC]P<CR LF>
Scale switch:
[CC]CGCHn<CR LF> or[CC]Qn<CR LF>
in which:
n = scale number (from 1 to 4)
Example:Q1+CR