3.2 DESCRIPTION OF THE STEPS
<< LAnG >> FIRMWARE LANGUAGE
Parameter
Language
Used Codepage (see section 7.2)
-
En
English
1252 Windows Latin 1
-
Fr
FranÇais
1252 Windows Latin 1
-
dE
Deutsch
1252 Windows Latin 1
-
ES
Español
1252 Windows Latin 1
-
Gr
Ellenika
1253 Windows Greek
-
It
Italiano
1252 Windows Latin 1
(!) En
<< nuM.SCA >> NUMBER OF CONNECTED SCALES (*)
- 1 scale.
- 2 scales.
- Remote (only remote scale): this value is not visible if one sets the
SEtuP >>
SEriAL >> rEAdEr
on
CoMAuX
.
(!) n.SC. 1
(*)
In case of approved instrument the parameter is read only.
For each connected scale, one is asked to configure the next steps:
<< CELtyP >>
CELL TYPE
This menu allows setting the type of cells used (analogue or digital):
in case of analogue cells it will be possible to enter the number of analogue
channels.
in case of digital cells / DGX conversion card, it will be possible to enter the number of cells forming the scale and
follow the instructions in section 3.3.6. Only load cells of the same model and the same capacity can compose two
digital platforms.
NOTE
:
The instrument is able to manage up to 4 analogue channels or 16 digital cells / 16 analogue load cells
converted as digital through DGX conversion cards.
(!) AnALoG
<< DGX.MOD >>
DGX FUNCTION MODE
- M.CELLS: Conversion into digital of each single analogue load cell.
- J.boX: for use of the manufacturer.
Follow the instructions in section 3.3.6.
(!) J.boX
<< DGX.NUM >>
NUMBER OF DGX CARDS
This menu allows setting the number of DGX composing ALL THE SCALES.
Follow the instructions in section 3.3.6.
<<
CEL.Add
>>
SET 485 CELLS ADDRESS
See section 3.3.7.