3590EKR, 3590EXP, 3590EXT, 3590 EBOX, CPWE, CPWET series indicator E-AF03_05.01_14.07_EN_T.doc
41
<< ZEro >>
TRANSMISSION OF SCALE ZERO COMMAND FROM THE INDICATOR
In this step one can enable the Zero scale transmission command: the command (not configurable) is
Z
followed by
a “CR”.
DISABLED
ENABLED
(!) DISABLED
<< tArE >>
REMOTE SCALE TARE SENDING
In this step one can enable the transmission of the Tare command from the indicator:
DISABLED
ENABLED
>> One will be requested to enter the command that is to be transmitted (up to 3 alphanumeric
characters) followed by a “CR”.
(!) DISABLED
<< MAn.tAr >>
REMOTE SCALE MANUAL TARE
In this step one can enable the transmission of the manual Tare command from the indicator:
Disable
disabled
VAL.CMd
first the value is transmitted and then the tare command
CMd.VAL
first the command is transmitted and then the tare value
If one sets
VAL.CMd
or
CMd.VAL
one will be asked to enter the command to be transmitted (up to 3 alphanumeric
characters) followed by a “CR”.
(!) Disable
<< rEq.WEi >>
REMOTE SCALE WEIGHT REQUEST
In this step one can enable the serial command which will be used to request the string from the remote scale,
when it is transmitted upon request.
DISABLED
ENABLED
>> It will be possible to set the request interval (001..up to 255 sec) and the serial command for
reading the weight (up to 4 alphanumeric characters).
(!) DISABLED
NOTE:
For the scale configuration of the remote scale, refer to the relative manual.
<< rEAdEr >>
READER PROTOCOL
Enabling data reception from external reader (See relative manual)
DISABLE
data reception disabled
COM.AUX
protocol enabled on the ComAux
COM.PRN
protocol enabled on the ComPrn
(!) DISABLE
<< r71.rEP >>
R71 REPEATER
If the R71620 is connected to the indicator, through this step it is possible to enable the dedicated protocol, for the
serial ports set with the “
riPE 6
” protocol.
DISABLED
ENABLED
(!) DISABLED
<< Prn.FMt
>>
PRINT CONFIGURATION
Through this step one can configure up to 30 print formats directly from the indicator.
In this step it is possible to choose the number of format to be configured; therefore enter, modify or eliminate the
print blocks following the instructions shown in section
7 PROGRAMMING THE PRINTOUTS
.
<< tErMin
>>
SET TERMINATOR TYPE
When connecting a printer it is possible to define the end of the print line, in the print blocks provides the terminator
print (indiT, see 7.3 section)
Cr
TERMINATOR CR (character 13 from ASCII table)
Cr LF
TERMINATOR CR LF (character 13 and character 10 from ASCII table)