Temporary view of message on the display: [CC]DISPNNVVVVVV<CR LF>
in which:
NN: display number of the indicator, (00 for 3590E LED display / CPWE weight
section, 01 for 3590E LCD display / CPWE data section)
V: character to be displayed (at least 1, cut off at the number of characters which
may be viewed by the indicated display)
The message remains for the time configured through the DINT command; if one selects to view the message permanently
on a display and one wants to cancel the operation, transmit the DISPNN command without any message: the display,
specified in the command (NN) goes back to view the usual information relative to the selected functioning mode.
Setting a display viewing interval:
[CC]DINTXXNNNN<CR LF>
in which:
XX: code which identifies the display (00 for 3590E LED display / CPWE weight
section, 01 for 3590E LCD display / CPWE data section)
NNNN: visualisation interval (in milliseconds), N is an ASCII hex character; for
example, to set a visualisation time of 2 seconds (therefore 2000 milliseconds),
which converted into hex become 07D0, the command becomes
DINT0007D0<CR><LF>.
By setting NNNN = 0000, the transmitted message with the DISP command (see above) remains permanently viewed on
the selected display.
With approved instrument
-
For the display 00 (00 for 3590E LED display / CPWE weight section), the maximum settable time is 5 seconds (5000
milliseconds, HEX 1388).
-
One should wait for the end of an eventual current visualisation before viewing a following one.
Data of last weigh made
[CC]LAST<CR LF>
Instrument’s answer:
If tare set = 0:
<I/O>, <Progressive>,<ID>, <IN Weight>,<OUT weight>,<IN-OUT difference>
If single weigh:
<I/O>, <Progressive>,<ID>, <Weight>,<Set Tare>,<Net>
in which:
<I/O> = I
Input weigh
O
Output weigh
< Progressive >
Progressive number of 6 digits which increases with each
pressing of
F6
or
F7
.
<ID> = weigh ID
<IN weight>
Input weight.
<OUT weight>
Output weight.
<IN-OUT difference>
Difference between <IN weight> and <OUT weight>
<Weight>
Weight (in input or in output).
<Set tare>
Set tare weight
<Net>
Difference between <Weight> and <Set Tare>.
NOTES:
-
The indicator’s answer is updated with each input, output or single weigh.
-
If the “
b tYPE
” protocol has been set, the answer to the command becomes the one described in the protocol itself (see
following paragraph); furthermore, the answer of the indicator is updated every input/output weighing cycle or single
weigh.