3590EKR, 3590EXP, 3590EXT, 3590 EBOX, CPWE, CPWET series indicator E-AF03_05.01_14.07_EN_T.doc
47
See section “WEIGHT ZOOM”
(USER MAN.REF.)
for the functioning details.
(!) Enable, 005 sec.
(§)
This step is visible only in case of CPWE indicator.
<< PoW.oFF >>
AUTO SWITCH OFF
One enables/disables the auto switch-off after the scale is not used for 5 minutes, with plate unloaded.
ENABLED
DISABLED
(!) DISABLED
<< bt.StAt >>
BATTERY LEVEL INDICATION
One selects whether to enable or disable the software check of the battery charge level: each time that the charge
goes down of a level, it is notified through the symbols on the LCD display (battery icon). See section 4.2.2
USER
MAN.REF.
ENABLED
DISABLED
NOTE
: by enabling the indication of the battery level, the backlight is automatically managed.
(!) DISABLED
<< baCkuP >>
INSTRUMENT DATA BACKUP
By pressing
ENTER
the indicator display shows
SurE?
: press the
ENTER
key to confirm or
C
to cancel the operation.
it will be requested to enable or disable the password for the instrument backup. if you confirm with enable it will be
necessary to insert a code that it will be request when you reload old configuration saved. After the default execution
is asked if one wants to enable the protection password. That password protects a possible new backup and the
defaults. The data restore from backup not needs the password insertion. In the default steps: standard default,
technical default, clearing of buffered ram, prints default or keys default, if a backup of the data is present, is asked if
one wants to execute the normal default by pressing the
ENTER
key or to restore the saved data by pressing the
F1
key.
<< dFLt >>
DEFAULT STANDARD
By pressing
ENTER
the indicator activates the default parameters (shown in bold and preceded by the exclamation
point at the end of each step) and the standard printouts; the display shows
SURE?
: press
ENTER
to confirm or
C
to
cancel the operation.
NOTE: THE CALIBRATION, THE DATABASES, THE INPUT TEXTS AND THE HEADINGS ARE NOT DELETED.
<< dFLt.t >>
TECHNICAL DEFAULT (*)
By pressing
ENTER
the indicator activates the default parameters (shown in bold and preceded by an exclamation
point at the end of each step), the default printouts, initialises the database and the alibi memory, cancels the input
texts, the heading and
THE CALIBRATION
; the display shows
SurE?
: press the
ENTER
key to confirm or
C
to cancel
the operation.
(*)
In case of approved instrument the step is not accessible.
<< PWd.SEt >>
SET ACCESS PASSWORD TO SET-UP ENVIRONMENT
One configures whether to enable or disable the access password to the technical menu:
ENABLED
DISABLED
By selecting
ENABLED
, the instrument predisposes itself for the password entry, made up of up to 5 digits; when
finished entering confirm with
ENTER
.
The settable values go from 0 to 65534.
See section 3 for the functioning specifics.
(!) DISABLED