9.3 LIST OF PRINT BLOCKS
LEGEND:
b
indicates a space character (ASCII 32 decimal character).
UM
unit of measure of the active scale (kg,
b
g,
b
t, lb).
UMD
unit of measure of the database (kg,
b
g,
b
t, lb).
+ T
terminator: depending on the setting of the
SEtuP
>>
SEriAL
>>
tErMin
“SET TERMINATOR TYPE” step of the
SET-UP environment, a CR or CRLF, LF or no terminator is added.
XXX*
These blocks do not work without the alibi memory (optional).
The weight field expands from right to left, with many spaces (ASCII 32 decimal character) for completing the field length.
NOTE
- The weight and weighing values expand from from right to left, with the necessary spaces in order to complete the field
length.
- The weighing numbers are increased with each input/output weighing cycle or with each single weigh.
9.3.1 ORDER BY KIND
CODE
PRINT FORMAT
GENERIC
300
PRINT END
307
DOTTED LINE
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- + T
308
PRINTS 3 CRLF
309
DATE / TIME FOR DP24/DP190
b
HH:MM
b
DD/MM/YY + T
318
PRINTS ON PC PORT
319
PRINTS ON PRINTER PORT
320
FORCES PRINTOUT
366
DATE
DD/MM/YY + T
367
TIME
HH:MM + T
368
DATE TIME
DD/MM/YY
b
HH:MM + T
369
FOLLOWING MACRO TERMINATOR SKIPS
372
HEADING 1
XXXXXXXXXXXXXXXXXXXXXXXX
in which XXXXXXXXXXXXXXXX are the 24 characters of the first line of the heading; just the entered characters
are printed, from left to right.
373
HEADING 2
XXXXXXXXXXXXXXXXXXXXXXXX
374
HEADING 3
XXXXXXXXXXXXXXXXXXXXXXXX
377
PRINTS TERMINATOR
CR or CRLF or NO TERMINATOR
CR or CRLF or NO TERMINATOR
378
PRINTS A SPACE
b
b
379
SCALE UNIT OF MEASURE
UM
380
DATABASE UNIT OF MEASURE
UM
392
PRINTS WEIGH ID
ID
b
:XXX + T
In which XXX is the weigh number, from 1 to 999; only the entered characters are printed, expanding from left to
right.
410
JUST WEIGHT ID VALUE
XXX
In which XXX is the weigh number, from 1 to 999; only the entered characters are printed, expanding from left to
right.
421
STANDARD KD PROTOCOL STRING
422
AF0X PROTOCOL STRING
Through the blocks 421 and 422 it is possible to print the STANDARD or AFXX serial string (see section 5.4
TRANSMISSION PROTOCOLS for the description); the terminator of the string depends on the setting of the
SEtuP >> SEriAL >>tErMin
step of the SET-UP environment (CR or CRLF or no terminator).
423
PRINTS TERMINATOR
CR or CRLF or NO TERMINATOR
424
RELEASES PAPER FOR TM295
425
ACTIVATES PAPER PRESENT SENSOR FOR TM295
426
ACTIVATES TIMEOUT FOR TM295