15)
Set the third range: select step
CAP.2
and press
ENTER
, set the value (minimum 100 maximum 999999) and press
ENTER
.
16)
Carry out the acquisition of the calibration points: select the
CALib.P
step and press
ENTER
.
The instrument will request the following in this order:
Number of signal linearization points: the "CALIBRATION POINTS" message will appear followed by " 1 "; enter the
value (from 1 to 8 points, besides ZERO) and press
ENTER
.
ZERO point: the message "UNLOAD THE SCALE AND PRESS ENTER" appears; unload the scale and press
ENTER
.
First linearization point: "Point 1" message will appear followed by the request to enter the value of the calibration
weight; enter the value with the numeric keyboard and press
ENTER
. It will be requested to put the calibration weight
on the scale (display LCD) and to press
ENTER
.
Following calibration points: as the above.
17)
if various scales need to be calibrated, press the
C
key twice until the display show “SEL.SCA”, select the following
scale to be calibrated and repeat all the operations from point 4).
If, on the other hand, the calibration is finished, press various times the
C
key until the instrument asks for saving and
confirming with
ENTER
.
3.3.2 LINEARIZATION POINTS
By entering in the
SEtuP >> ConFiG >> CALib >>
PointS
step it’s possible to access a menu which allows to view/modify
the linearization points of the last calibration made:
ConFiG (*)
SEtuP
Calib
PointS
...
...
...
POINT
ADC.POINT
WEIGHT
0
72461
0.00
ACT.1
182567
1.00
POINT
ADC.POINT
WEIGHT
1
182567
1.00
ACT.2
279939
1.89
…
…
…
POINT
ADC.POINT
WEIGHT
7
XXXXXX
XXXX.XX
ACT.8
XXXXXX
XXXX.XX