Troubleshooting SCSI Controllers and Devices
The flow chart in Figure 4-8 shows how to troubleshoot a SCSI
controller or device.
Start
followed by the slot
number of the SCSI bus you
are testing. Then press Return.
Does the drive appear in
the cnfg display?
Make sure the SCSI and power cables
are connected to the drive and that
there is a terminator on the SCSI
connecton on the last external drive in
the SCSI bus.
Make sure each drive in the SCSI bus
has a unique ID from 0 to 6.
Does the drive appear in the
cnfg display now?
Replace the drive.
(Continued)
WS33M100
No
Yes
End
End
Yes
No
cnfg,
Type
Type
, followed by the slot
number of the SCSI controller. Then
press Return.
init
Figure 4-8. Troubleshooting SCSI controllers and devices
Identifying Failed FRUs
4–27