ENTRY 2
**********************
--------------EVENT INFORMATION ------------
EVENT CLASS
OPERATIONAL EVENT
OS EVENT TYPE
250
ASCII MSG
SEQUENCE NUMBER
6
OPERATING SYSTEM
ULTRIX 32
OCCURRED/LOGGED ON
Tue Jan 22 14:58:40 1991
OCCURRED ON SYSTEM
ft3
SYSTEM ID
x82030230
HW REV: x30
FW REV: x2
CPU TYPE: R4000
PROCESSOR TYPE
KN04-BA
MESSAGE
ioasicint: memory read error
Analyzing the Memory Error Example
The following list describes
the useful information in ENTRY 1 and ENTRY 2. Since this
is a memory error, the last entries under MEM REG in ENTRY
1 are of particular interest because they identify which SIMM
failed.
The ERROR SYNDROME field indicates that this is a
memory parity error.
The following MEM REG fields list details about the
memory failure:
The CNT fields list the count of hard (recurred on both
read and write operations), soft (recurred on read, but
cleared on write), and transient (didn’t recur on read)
errors.
The DATA BIT IN ERROR statement indicates that a
data bit (rather than a parity bit) failed.
The BYTE IN ERROR can be either high or low.
The MEMORY PARITY ERROR field lists the type
(hard, soft, transient) of error for this entry.
D0-15 indicates that the low SIMM failed. The low
SIMM is the left SIMM in a bank, looking from the
front, labeled D0-15 on the system module. The value
D16-31 in this position indicates that the high SIMM
failed. The high SIMM is the right SIMM in a bank,
labeled D16-31 on the module. BANK tells which bank
of memory failed. The eight banks are labeled 0 to 7
on both sides of the memory SIMMs. To replace the
3–14
Troubleshooting Tools
Содержание DECstation 5000/100 Series
Страница 20: ......
Страница 24: ......
Страница 36: ......
Страница 55: ...LJ 02972 TI0 MLO 010159 Figure 2 10 System Boot ROM Switches Service Operations 2 19...
Страница 139: ...WS33O125 CPU module CPU module connector Front view Back view Figure 5 6 33 MHz CPU module Base System FRUs 5 11...
Страница 140: ...LJ 02971 TI0 MLO 010159 Figure 5 7 50 MHz R4000 based CPU module 5 12 Base System FRUs...
Страница 151: ...WS33M076 Figure 5 14 Removing a memory module Base System FRUs 5 23...
Страница 153: ...WS33M075 Figure 5 15 Installing a memory module Base System FRUs 5 25...
Страница 164: ......
Страница 206: ......
Страница 356: ......
Страница 388: ......