Table D-8 lists error codes and descriptions used in SCC pins
test error messages.
Table D-8. SCC Pins Test Error Codes and Descriptions
Error Code and
Description
Meaning
1:Ln
N
Invld
param [
xxxxx
]
The number used in the test command to specify the
loopback was invalid.
N
represents the number of the
serial line in which the error occurred.
xxxxx
represents
the first two characters of the invalid value that was
specified.
2:Ln
N
Strtup
R-
xx
xptd=
yy
actl=
zz
|
pins
|
Test failed to generate the expected SCC status bits.
N
represents the number of the serial line in which the
error occurred. The Startup R value is the number of SCC
register that contains the status bits. The xptd value is
the expected status bits. The actl value is the actual status
bits. (pins) represents the pin pairs for which the test was
set up.
3: Ln
N xxxxx
Pins failed to respond properly.
xxxxx
represents the
numbers of one or more pin pairs that failed the test.
D–18
Base System Test Commands and Messages
Содержание DECstation 5000/100 Series
Страница 20: ......
Страница 24: ......
Страница 36: ......
Страница 55: ...LJ 02972 TI0 MLO 010159 Figure 2 10 System Boot ROM Switches Service Operations 2 19...
Страница 139: ...WS33O125 CPU module CPU module connector Front view Back view Figure 5 6 33 MHz CPU module Base System FRUs 5 11...
Страница 140: ...LJ 02971 TI0 MLO 010159 Figure 5 7 50 MHz R4000 based CPU module 5 12 Base System FRUs...
Страница 151: ...WS33M076 Figure 5 14 Removing a memory module Base System FRUs 5 23...
Страница 153: ...WS33M075 Figure 5 15 Installing a memory module Base System FRUs 5 25...
Страница 164: ......
Страница 206: ......
Страница 356: ......
Страница 388: ......