Table 4-2 (Cont.). Interpreting Base System Test Error Messages Displayed on the
Monitor
Test Listed in the
Error Message
Component Tested
Corrective Action
misc/wbpart
Memory modules
Refer to ‘‘Troubleshooting the Memory
Modules’’ later in this chapter to
troubleshoot.
ni/cllsn
ni/common
ni/crc
ni/cntrs
ni/dma1
ni/dma2
ni/esar
ni/ext-lb
ni/int
ni/int-lb
ni/m- cst
ni/promisc
ni/regs
ni/setup
Base system Ethernet
controller
Refer to ‘‘Troubleshooting an Ethernet
Controller’’ later in this chapter to
troubleshoot.
rtc/nvr
rtc/period
rtc/regs
rtc/time
System module
Replace the system module. Refer to
‘‘Removing and Installing a System
Module’’ in Chapter 5 for directions.
scc/access
scc/enable
scc/io
scc/regs
scc/pins
scc/tx-rx
Serial line controllers and
devices attached to them
Refer to ‘‘Troubleshooting a Printer,
Modem, or Other Serial Line Device’’
later in this chapter to troubleshoot.
scsi/cntl
scsi/sdiag
scsi/target
Base system SCSI
controller or device
Refer to ‘‘Troubleshooting SCSI
Controllers and Devices’’ later in this
chapter to troubleshoot.
(continued on next page)
Identifying Failed FRUs
4–17
Содержание DECstation 5000/100 Series
Страница 20: ......
Страница 24: ......
Страница 36: ......
Страница 55: ...LJ 02972 TI0 MLO 010159 Figure 2 10 System Boot ROM Switches Service Operations 2 19...
Страница 139: ...WS33O125 CPU module CPU module connector Front view Back view Figure 5 6 33 MHz CPU module Base System FRUs 5 11...
Страница 140: ...LJ 02971 TI0 MLO 010159 Figure 5 7 50 MHz R4000 based CPU module 5 12 Base System FRUs...
Страница 151: ...WS33M076 Figure 5 14 Removing a memory module Base System FRUs 5 23...
Страница 153: ...WS33M075 Figure 5 15 Installing a memory module Base System FRUs 5 25...
Страница 164: ......
Страница 206: ......
Страница 356: ......
Страница 388: ......