225
Allocate corresponding X terminal with function 27 (Length count
input) in applications. If the pulse frequency is high, X5/HDI must
be used.
PE.08
Set count value
Setting Range: 1
~
65535
1000
PE.09
Designated count value
Setting Range: 1
~
65535
1000
The count value needs to be collected by X terminal. Allocate the corresponding X terminal
with function 25 (Counter input) in applications. If the pulse frequency is high, X5/HDI must
be used.
When the count value reaches the set count value (PE.08), the DO terminal allocated with
function 8 (Set count value reached) becomes ON. Then the counter stops counting.
When the counting value reaches the designated counting value (PE.09), the DO terminal
allocated with function 9 (Designated count value reached) becomes ON. Then the counter
continues to count until the set count value is reached.
PE.09 should be equal to or smaller than PE.08
Figure 6-37 Reaching the set count value and designated count value
6.16 AI/AO Correction and AI Curve Setting
(
Group PF
)
PF.00
VI measured voltage 1
Setting Range:
Factory-corrected