233
Wrong setting of motor
overload protection factor
Set the factor right
Motor chocked or sudden
change of load
Check load
E-11 Under voltage
in running
Grid voltage is low
Check grid voltage
E-12 Output lack
phases
Cable between Inverter and
motor is fault
Check the peripheral fault
Output 3-phases un balance
Check motor 3 phases winding
Drive board fault
Contact supplier
IGBT module fault
Contact supplier
Control board connecting wire
or plug-in unit loose
Check and re-wiring
E-13 Peripheral
fault
External fault terminals closed Check the reason
E-14 Current
detecting
circuit fault
Loose wiring or terminal
connections
Check and re-wiring
Auxiliary power source
damaged
Contact supplier
Hall component damaged
Contact supplier
Amplifier circuit abnormal
Contact supplier
E-15 RS232/485
Communicatio
n fault
Baud rate setting incorrect
Set baud rate properly
Serial port communication fault Press Key to reset or contact
supplier
Improper fault alarm parameter
setting
Revise function code PC group
STOP