177
The output pulse frequency of the FMP terminal ranges from 0.01 kHz to "Maximum FMP
output frequency" (P5.09). The value of P5.09 is between 0.01 kHz and 100.00 kHz.
The output range of AO1 and AO2 is 0–10 V or 0–20 mA.
The relationship between pulse and analog output ranges and
corresponding functions is listed in the following table.
Value
Function
Range (Corresponding to Pulse or Analog
Output Range 0.0%–100.0%)
0
Running frequency
0 to maximum output frequency
1
Set frequency
0 to maximum output frequency
2
Output current
0
~
2 times of rated motor current
3
Output current
0.0A
~
1000.0A
4
Output torque (absolute
value)
0 to 2 times of rated motor torque
5
Output torque (actual
value)
-2 times of rated motor torque to 2 times of rated
motor torque
6
Output voltage
0
~
1.2 times of rated AC drive voltage
7
Output voltage
0.0V
~
1000.0V
8
Motor rotational speed
0 to rotational speed corresponding to
maximum output frequency
9
Output power
0
~
2 times of rated power
10
VI input
0
~
10V
11
CI input
0
~
10V
(
or 4
~
20mA
)
12
Pulse input
0.01kHz
~
100.00kHz
13
Communication setting
0.0%
~
100.0%
14
Length
0 to maximum set length