6.49. (XAPM) POWER MANAGEMENT
(*) When going to sleep immediately using the ’I’ qualifier the saving mode
is not preserved. i.e. after the unit wakes up the unit ends the power saving
mode.
6.49.1
Examples
Activate the power saving mode. Only the vehicle’s ignition may awake the
1
unit, and when awaken, the unit must remain up for 20 minutes:
>
SXAPMA000000010000020m
<
Activate the power saving mode. Any input but the 24v/12v detector may
2
awake the unit, and the unit has to awake every 2 hours. Use default values
for the rest.
>
SXAPMA000001011111DDDDDDDD002h
<
To configure the unit to go to sleep mode any time the external power
3
is removed and to go back to normal mode when the power is connected
again:
1. Create an event triggered when the power signal (F13) goes low that
activates the Power Saving mode; making sure the Power input is in-
cluded on the signals to be monitored while on sleep state:
>
SED00SV0;F13-;ACT=SXAPMA
<
No input mask specified, so any input, particularly the power de-
tector will drive the unit back to normal mode.
2. Create an event triggered when the power signal goes high that deac-
tivates the power saving mode:
>
SED01SV0;F13+;ACT=SXAPME
<
Having this configuration the unit will go to sleep mode 2 minutes
after disconnecting the primary power source.
208
Содержание Antares SB
Страница 1: ......
Страница 2: ...Antares SB TM GSM User s Manual FW 5 21 Digital Communications Technologies April 15 2008...
Страница 37: ...2 1 POWER SUPPLY 35...
Страница 38: ...2 1 POWER SUPPLY 36...
Страница 42: ...2 5 CONNECTION DIAGRAMS 40...
Страница 141: ...6 Unit s TAIP reference...
Страница 191: ...6 32 XADM DIAGNOSTIC MESSAGE 189...
Страница 228: ......
Страница 229: ......