5.11. MAIN-POWER-LOSS ALARM
#condition
>SGS0110150<
#Start 16 seconds timer when the speed
#falls off the previously set value and
#as long as the user signal is set
>SED14SV0;S01!U00&+;ACT=SGC02TC00016<
#Stop the timer when the speed condition
#is violated
>SED15SV0;S01+;ACT=SGC02U<
#Ignition cut event
#Sets output 4 high and
#sends a report to DA 5
>SED13NV5;C02U00&+;ACT=SSSXP41<
#Restore (set low) the user signal
>SED16SV0;E13+;ACT=SSSU000<
#-------------------------------------------
#--Reconnection event for DP 00-------------
>SED49NV4;A00+<
#-------------------------------------------
#end
5.11
Main-power-loss alarm
If the units has a built-in back-up battery
5
, it can send a report whenever
the main power source gets disconnected. To do so we use the
F13
signal.
>
SED07NV5;F13-
<
We choose event 07 for no particular reason. Continuing with our example,
this will make event 07 to be reported to the AVL server and the Phone
Number 912345678 any time the main power source gets disconnected.
5.11.1
Script
Adding this message to the script is trivial so it is a task left to the reader.
5.12
Using the sleep mode
Refer to the
XAPM
TAIP message.
5
Built-in back-up battery is optional