6.30. (XACR) COUNTER REPORT
6.30
(XACR) Counter Report
Qualifiers
:
S
,
R
Use this message to have the unit generate a
TX
message to a
Destination
Point
(DP) or
Destination Address
(DA) containing an specific counter’s
(see
GC
message) value. The message takes a counter’s index, and a DP or
DA index. The message has the following format:
AABB
Chars
Item
Format
Value
Meaning
2
Counter
Index
AA
00-19
Counter’s index whose value is going
to be reported on a
TX
message.
2
Destination
BB
Destination for the
TX
message:
If the first character of the field is the
letter
A
it is understood by the unit
that the second digit holds a
Destina-
tion Address
. If both characters of the
field are digits, the unit assumes the
user is specifying a
Destination Point
.
Destination Addresses range from 0 to
9.
Destination Points range from 00 to
15.
6.30.1
Reported Message
After receiving the
XACR
command the unit will send a
TX
message to the
selected DP/DA with the selected counters value.
The message for a counter configured to count distance is as follows:
>
RTXDistancer 2 = 10 x(1000m)
<
This is going to be displayed on the AVL software as:
Distancer 2 = 10 x(1000m)
The first word holds the type of counter, then the counters index is shown.
After the equal value the counters value followed by the delta factor config-
ured for the counter.
Other types of counter messages are:
Timer 5 = 2 x(300s)
Distancer 2 = 70 x(1000m)
Counter 3 = 1200 x (10)
If the counter’s index is followed by
(S)
it means the counter is actually
suspended.
185
Содержание Antares SB
Страница 1: ......
Страница 2: ...Antares SB TM GSM User s Manual FW 5 21 Digital Communications Technologies April 15 2008...
Страница 37: ...2 1 POWER SUPPLY 35...
Страница 38: ...2 1 POWER SUPPLY 36...
Страница 42: ...2 5 CONNECTION DIAGRAMS 40...
Страница 141: ...6 Unit s TAIP reference...
Страница 191: ...6 32 XADM DIAGNOSTIC MESSAGE 189...
Страница 228: ......
Страница 229: ......