6.49. (XAPM) POWER MANAGEMENT
A[[[[BBBBBCDEFGHI]JJJJ]KKKK]LLLL]
Chars
Item
Format
Value
Meaning
1
Action
A
Action:
A:
Activate the power saving mode.
E:
End
any
active
power
saving
mode.
I:
Go to power saving mode immedi-
ately(*).
5
Flags
BBBBB
Reserved flags. Should be set to
11111
1
Power
C
flag
Set to 1 to monitor the power detector input
when in sleep mode.
Set to 0 to ignore this
input on sleep mode.
1
24v/12v
D
flag
Ignored. i.e. Always set to ’0’.
1
Ignition
E
flag
Set to 1 to monitor the ignition.
1
IP4
F
flag
Set to 1 to monitor input 4.
1
IP3
G
flag
Set to 1 to monitor input 3.
1
IP2
H
flag
Set to 1 to monitor input 2.
1
IP1
I
flag
Set to 1 to monitor input 1.
4
Wake up time
JJJJ
This is the Wake-up time that tells the unit how
long to stay awake after returning from sleep
mode. If the field value is entered as
DDDD
the
default time of 2 minutes is used. Wake up time
is an integer value that can accept the scalar
factors
m
or
h
on the least significant field to
indicate minutes or hours, if no scalar factor is
included, a value of seconds is assumed.
The
minimum value is 1 minute, the maximum is
999h (999 hours).
4
Inactivity time-
out
KKKK
This is the communication inactivity timeout in
seconds, used when the unit is ready to go to
sleep while it has detected over-the-air commu-
nication activity. If the field value is entered as
DDDD
the default time of 1 minute is used. This
is an integer value that does not support scalar
factors.
The minimum value is 60 seconds; the
maximum is 3600 seconds.
4
Wake up inter-
val
LLLL
This is the wake-up interval used by the unit
to return from sleep to normal mode on a time
basis. If this field is not included, the unit will
not wake-up on a time basis and only an input
change may get the unit back to normal mode.
The unit will wake up when the elapsed time
since entering sleep mode equals the wake-up
interval. This is an integer value that can accept
the scalar factors
m
or
h
on the least significant
field to indicate minutes or hours, if no scalar
factor is included, a value of seconds is assumed.
The minimum value is 1 minute; the maximum
is 255h (255 hours).
207
Содержание Antares SB
Страница 1: ......
Страница 2: ...Antares SB TM GSM User s Manual FW 5 21 Digital Communications Technologies April 15 2008...
Страница 37: ...2 1 POWER SUPPLY 35...
Страница 38: ...2 1 POWER SUPPLY 36...
Страница 42: ...2 5 CONNECTION DIAGRAMS 40...
Страница 141: ...6 Unit s TAIP reference...
Страница 191: ...6 32 XADM DIAGNOSTIC MESSAGE 189...
Страница 228: ......
Страница 229: ......