4.5. *EVENT MACHINE
•
Sense the vehicle’s ignition and speed to create IDLE, STOP and
MOVING events.
•
Reduce a report frequency when the unit starts roaming on GSM.
•
Sense the primary power presence and go to low power consumption
mode or on the contrary, increase the reporting criteria to report it
as an abnormal condition.
•
Create an intelligent
Time and Distance
report which automatically
increases the reporting criteria to a top as the vehicle travels fast and
decreases it to a minimum when the vehicle travels at low or zero
speeds.
•
Create a confirmation report that confirms that a remotely-set output
has reached the set state.
4.5.2
Actions
Once you have defined a trigger (and/or a set of triggers) the next step for
configuring the
Antares SB
TM
event machine, is to tell the unit what to do
when a trigger goes off. There are two types of actions the unit may take
when a trigger goes off. These are the
report
action and the
user-defined
action.
Report action
When the
event machine
detects that a trigger goes off it uses the configura-
tion of the
report
action to generate a report. A
report
action configuration
includes
routing options
and a
type of report
.
The
routing options
tell the unit where to report the occurrence of the spe-
cific event. The report destinations may be
9
IP addresses (or host names),
cellular phone numbers, unit’s serial port. It could also be a silent report
which is not reported to any destination
10
.
The
type of report
is used to tell the unit which kind of TAIP report
message generate when reporting to a destination. The unit supports two
reporting messages:
•
ET
Time-only report. Use
T
as Message ID on an
event definition
. See
the
ED
message.
•
EV
Event report: Use
V
as Message ID on an
event definition
. See the
ED
message.
9
With the
routing options
a single destination or a group of destinations may
be specified. This makes the unit able of sending the same report to several
destinations at the same time.
10
This feature is useful when using events to trigger other events or when a
user-
specified
action is specified but no reporting is desired
79
Содержание Antares SB
Страница 1: ......
Страница 2: ...Antares SB TM GSM User s Manual FW 5 21 Digital Communications Technologies April 15 2008...
Страница 37: ...2 1 POWER SUPPLY 35...
Страница 38: ...2 1 POWER SUPPLY 36...
Страница 42: ...2 5 CONNECTION DIAGRAMS 40...
Страница 141: ...6 Unit s TAIP reference...
Страница 191: ...6 32 XADM DIAGNOSTIC MESSAGE 189...
Страница 228: ......
Страница 229: ......