6.35. (XAFU) FIRMWARE UPGRADE (OVER THE AIR)
6.35
(XAFU) Firmware Upgrade (Over the air)
Qualifiers
:
S
,
R
This message starts an over-the-air firmware update process. This message
returns TAIP error 69 or 90 when used on a unit with this feature disabled.
The message has the following format:
ABBBBCCDD
Chars
Item
Format
Value
Meaning
1
Server
A
0-1
Firmware server: Use 0 for DCT’s servers, 1 for
user-defined server
a
.
4
Firmware Ver-
sion
BBBB
Firmware Version to download. The first two
letter must always be 05. The last two indicate
the firmware family. For example, to update to
FW 5.21, BBBB should be set to
0521
.
2
Firmware type
CC
Type of version to download. Always set this
value to
SV
.
2
Diagnostics
route
DD
Indicates where to send the diagnostic reports of
the download/installation process. Use a num-
ber between 00 and 15 to indicate a
Destination
Point. Use the letter A plus a number between
0 and 9 to use a
Destination Address
.
a
Contact Digital Communications Technologies for more information on this.
For example, to update to firmware version 5.21:
>
SXAFU00521SV15
<
Notice that diagnostic messages will be sent to the serial port (DP 15).
If diagnostic messages have to be sent to
Destination Address 5
, use:
>
SXAFU00521SVA5
<
See the
Firmware Upgrade
section on the
Operation
chapter for more infor-
mation.
193
Содержание Antares SB
Страница 1: ......
Страница 2: ...Antares SB TM GSM User s Manual FW 5 21 Digital Communications Technologies April 15 2008...
Страница 37: ...2 1 POWER SUPPLY 35...
Страница 38: ...2 1 POWER SUPPLY 36...
Страница 42: ...2 5 CONNECTION DIAGRAMS 40...
Страница 141: ...6 Unit s TAIP reference...
Страница 191: ...6 32 XADM DIAGNOSTIC MESSAGE 189...
Страница 228: ......
Страница 229: ......