3.4. OUTPUTS
3.4
Outputs
The unit has 4 discrete outputs located on the main molex connector.
Given their 2A current capacity they can drive a wide range of loads.
The outputs are of
Open Drain
type with no pull-up resistor. Mean-
ing that the user has to provide a pull-up resistor to any positive
voltage (
30V
max.) to detect an inactive output by voltage. Each
output can drive a continuous current of 2A.
The electrical conditions are:
Logical State
Electrical state
Active
0V
Inactive
Open or the pull-up voltage (max
30V
)
Outputs may be driven locally or remotely using the TAIP console
or the unit can be configured to automatically take outputs’ actions
depending on different situations. The
Event Machine’s
signals asso-
ciated to outputs are:
Output
Signal name
Old signal name
5
Output 1
XP1
G04
Output 2
XP2
G05
Output 3
XP3
G06
Output 4
XP4
G07
Outputs activation and deactivation is controlled by the
SS
TAIP
message.
To activate output 3 send to the unit:
Example
>
SSSXP31
<
To query its status:
>
QSSXP3
<
and the unit should return:
>
RSSXP31
<
To deactivate the output:
>
SSSXP30
<
Making the
Antares SB
TM
automatically drive an output:
Example
Use the
SS
message as an user-action on an event definition, see the
Event Machine
section on the
Configuration
chapter and the
ED
mes-
46
Содержание Antares SB
Страница 1: ......
Страница 2: ...Antares SB TM GSM User s Manual FW 5 21 Digital Communications Technologies April 15 2008...
Страница 37: ...2 1 POWER SUPPLY 35...
Страница 38: ...2 1 POWER SUPPLY 36...
Страница 42: ...2 5 CONNECTION DIAGRAMS 40...
Страница 141: ...6 Unit s TAIP reference...
Страница 191: ...6 32 XADM DIAGNOSTIC MESSAGE 189...
Страница 228: ......
Страница 229: ......