3.3. INPUTS/IGNITION
Logical State
Electrical State
Active
0V
to
1V
Inactive
2.9V
to
32V
or Open
For the ignition input:
State
Voltage range
Ignition ON
5.8V
to
32V
Ignition OFF
0V
to
4.8V
or Open
For addition Inputs’ state can be consulted locally or remotely at any
time with the TAIP console.
Inputs are used to create events’ triggers on the
Event Machine
thus
generating reports depending on the inputs’ state/changes.
To create input dependent events and to consult inputs’ state the
Event Machine’s
IP
signals are used. These signals are
true
whenever
the corresponding input is
true
. For information on signals consult
the
Event Machine
section on the
Configuration
chapter.
The corresponding signals are:
Input
Signal name
Old signal name
Input 1
IP1
G00
Input 2
IP2
G01
Input 3
IP3
G02
Input 4
IP4
G03
Ignition
F00
F00
Inputs can be monitored with the
SS
TAIP message.
To consult the state of Input 3:
Example
Using the TAIP console send to the unit:
>
QSSIP3
<
For an active input (i.e. input 3 at GND) the unit returns:
>
RSSIP31
<
and when the input is not active (i.e. input 3 at any voltage
4
or
disconnected):
>
RSSIP30
<
4
The maximum supported voltage for inputs is 32 volts.
45
Содержание Antares SB
Страница 1: ......
Страница 2: ...Antares SB TM GSM User s Manual FW 5 21 Digital Communications Technologies April 15 2008...
Страница 37: ...2 1 POWER SUPPLY 35...
Страница 38: ...2 1 POWER SUPPLY 36...
Страница 42: ...2 5 CONNECTION DIAGRAMS 40...
Страница 141: ...6 Unit s TAIP reference...
Страница 191: ...6 32 XADM DIAGNOSTIC MESSAGE 189...
Страница 228: ......
Страница 229: ......