6.37. (XAGB) BACK-UP BATTERY LEVELS
6.37
(XAGB) Back-up Battery levels
This message is used to configure back-up battery levels associated to ”B”
Qualifiers
:
Q
,
S
,
R
signals. The message has the following format:
AABCCCCC
Chars
Item
Format
Value
Meaning
2
Battery
level ID
AA
00-04
Identification code assigned to the
Battery level.
1
Active
flag
B
flag
V: Battery level defined as a volt-
age value.
P: Battery level defined as a per-
centage value.
U: Delete the battery level.
5
Battery
level
CCCCC
A millivolts value or percentage
value.
See the
Back-up battery
section on the
Operation
chapter for examples.