5.7. START/STOP MONITORING
>SED37NV4;TD8+<
#Input report event
>SED05NV5;IP3+<
#User text message for event 05
>SXATM05Input 3 has been activated!<
#Ignition ON event
>SED19NV4;F00+<
#Ignition OFF event
>SED20NV4;F00-<
#Set an speed limit of 65mph
>SGS0710650<
#Start a 15 secs. timer when
#speed limit is violated
#(silent event)
>SED40SV0;S07+;ACT=SGC00TC00015<
#Stop the timer when the speed falls
#below the limit
#(silent event)
>SED41SV0;S07-;ACT=SGC00U<
#Create the violation report
>SED10NV4;C00+<
#Drive a LED on output 1 ON
#when the speed goes beyond the limit
#(silent event)
>SED42SV0;S07+;ACT=SSSXP11<
#Drive a LED on output 1 OFF
#when the speed falls off the limit
#(silent event)
>SED43SV0;S07-;ACT=SSSXP10<
#end
5.7
START/STOP monitoring
In this example we are going to create two reporting events that reflect two
possible situations for a vehicle: a vehicle STOP and a vehicle re-start or
first start (simply START).
Note: This example continues working on the
example that has been worked so far, the
Getting Started
+ SMS reporting