4.5. *EVENT MACHINE
a “periodic” sort of signal which is suitable for a Time And Distance
report.
An example of using these messages to define a signal:
Defining the speed signal
S06
to be
true
whenever the vehicle’s speed ex-
Example
ceeds
55mph
and false whenever the speed is below:
>
SGS0610550
<
Now the speed signal
S06
can be used on an event’s definition to gener-
ate a report every time the vehicle exceeds
55mph
:
>
SED33NT3;S06+
<
We just defined event 33 to send an ET report to DA 3 every time the
S06
signal switches from
false
to
true
, that’s what the + sign does. The
report will only be generated once. In order for the event to trigger again
the
S06
signal has to become
false
first and then
true
again. This means
that the speed excess is going to be reported every time the speed goes from
anything less than
55mph
to a larger value but not every time the speed
remains at the larger value.
4.5.5
Examples
Some examples about the use of the event machine are presented next.
For complete examples containing both the
Event Machine
and the other
parameters necessary to get the unit working refer to the
Scenarios and
Examples
chapter. To understand the events’ configuration format refer to
the
ED
message on the TAIP reference.
Configuring two events on the
Event Machine
to generate an ignition report:
Example
The ignition ON event may be defined as:
>
SED18NV4;F00+
<
And the Ignition OFF event:
>
SED19NV4;F00-
<
Both events’
routing actions
indicate that the destination of the report is
the DA 4 and that
EV
is the reporting message to generate. Both events use
a simple trigger consisting of a one-signal-only condition,
F00
which is the
vehicle’s ignition signal.
Creating an event to detect when the vehicle leaves a defined region:
Example
When a vehicle is outside the perimeter defined by the polygon that de-
fines a region, the corresponding region’s signal is set to false. To generate
an event whenever a vehicle leaves the region the region’s signal has to be
monitored for the
true
to
false
transition (this is done with the minus sign
on the event’s trigger):
>
SED24NV7;R26-
<
This event is going to be reported to DA 7 which has to be defined be-
86
Содержание Antares SB
Страница 1: ......
Страница 2: ...Antares SB TM GSM User s Manual FW 5 21 Digital Communications Technologies April 15 2008...
Страница 37: ...2 1 POWER SUPPLY 35...
Страница 38: ...2 1 POWER SUPPLY 36...
Страница 42: ...2 5 CONNECTION DIAGRAMS 40...
Страница 141: ...6 Unit s TAIP reference...
Страница 191: ...6 32 XADM DIAGNOSTIC MESSAGE 189...
Страница 228: ......
Страница 229: ......