NOTE
Parameter copy is not possible with Numeric Local Control
Panel (LCP101).
Select one of the following modes:
Status Mode: Displays the status of the frequency converter
or the motor.
If an alarm occurs, the NLCP automatically switches to status
mode.
A number of alarms can be displayed.
Quick Set-up or Main Menu Mode: Display parameters and
parameter settings.
130BA191.10
1
Auto
on
Reset
Hand
on
Off
Menu
Status
Quick
Setup
Main
Menu
Back
2
3
4
OK
On
Alarm
Warn.
Setup
Illustration 2.1 Numerical LCP (NLCP)
130BP077.10
22.8
rpm
Setup 1
Illustration 2.2 Status display example
Indicator lights (LEDs):
•
Green LED/On: Indicates if control section is on.
•
Yellow LED/Wrn.: Indicates a warning.
•
Flashing red LED/Alarm: Indicates an alarm.
Setup 1
130BP078.10
A 17
Illustration 2.3 Alarm display example
Menu key
[Menu] Select one of the following modes:
•
Status
•
Quick Setup
•
Main Menu
Main Menu is used for programming all parameters.
The parameters can be accessed immediately unless a
password has been created via
,
0-61 Access to Main Menu w/o Password
or
0-66 Access to Personal Menu w/o Password
Quick Setup is used to set up the frequency converter using
only the most essential parameters.
The parameter values can be changed using the up/down
arrows when the value is flashing.
Select Main Menu by pressing the [Menu] key a number of
times until the Main Menu LED is lit.
Select the parameter group [xx-__] and press [OK]
Select the parameter [__-xx] and press [OK]
If the parameter is an array parameter select the array
number and press [OK]
Select the wanted data value and press [OK]
Navigation Keys [Back] for stepping backwards
Arrow [
▼
] [
▲
] keys are used for manoeuvring between
parameter groups, parameters and within parameters.
[OK] is used for choosing a parameter marked by the cursor
and for enabling the change of a parameter.
130BP079.10
M enu
S ta tus
Q uick
S etup
M ain
M enu
P 2-03
S etup 1
Operation Keys
Keys for local control are found at the bottom of the control
panel.
130BP046.10
Hand
on
Off
Auto
on
Reset
Illustration 2.4 Operation keys of the numerical CP (NLCP)
[Hand on] enables control of the frequency converter via the
LCP. [Hand on] also starts the motor and it is now possible to
enter the motor speed data by means of the arrow keys. The
key can be selected as
Enable
[1] or
Disable
[0] via
.
External stop signals activated by means of control signals or
a serial bus will override a 'start' command via the LCP.
How to Programme
VLT
®
HVAC Drive Programming Guide
MG.11.CB.02 - VLT
®
is a registered Danfoss trademark
15