13-02 Stop Event
Option:
Function:
[6]
Current limit
See parameter group 5-3* for further
description.
[7]
Out of current
range
See parameter group 5-3* for further
description.
[8]
Below I low
See parameter group 5-3* for further
description.
[9]
Above I high
See parameter group 5-3* for further
description.
[10]
Out of speed range
[11]
Below speed low
See parameter group 5-3* for further
description.
[12]
Above speed high
See parameter group 5-3* for further
description.
[13]
Out of feedb. range See parameter group 5-3* for further
description.
[14]
Below feedb. low
See parameter group 5-3* for further
description.
[15]
Above feedb. high
See parameter group 5-3* for further
description.
[16]
Thermal warning
See parameter group 5-3* for further
description.
[17]
Mains out of range See parameter group 5-3* for further
description.
[18]
Reversing
See parameter group 5-3* for further
description.
[19]
Warning
See parameter group 5-3* for further
description.
[20]
Alarm (trip)
See parameter group 5-3* for further
description.
[21]
Alarm (trip lock)
See parameter group 5-3* for further
description.
[22]
Comparator 0
Use the result of comparator 0 in the
logic rule.
[23]
Comparator 1
Use the result of comparator 1 in the
logic rule.
[24]
Comparator 2
Use the result of comparator 2 in the
logic rule.
[25]
Comparator 3
Use the result of comparator 3 in the
logic rule.
[26]
Logic rule 0
Use the result of logic rule 0 in the
logic rule.
[27]
Logic rule 1
Use the result of logic rule 1 in the
logic rule.
[28]
Logic rule 2
Use the result of logic rule 2 in the
logic rule.
13-02 Stop Event
Option:
Function:
[29]
Logic rule 3
Use the result of logic rule 3 in the
logic rule.
[30]
SL Time-out 0
Use the result of timer 0 in the logic
rule.
[31]
SL Time-out 1
Use the result of timer 1 in the logic
rule.
[32]
SL Time-out 2
Use the result of timer 2 in the logic
rule.
[33]
Digital input DI18
Use the value of DI18 in the logic rule
(High = TRUE).
[34]
Digital input DI19
Use the value of DI19 in the logic rule
(High = TRUE).
[35]
Digital input DI27
Use the value of DI27 in the logic rule
(High = TRUE).
[36]
Digital input DI29
Use the value of DI29 in the logic rule
(High = TRUE).
[37]
Digital input DI32
Use the value of DI32 in the logic rule
(High = TRUE).
[38]
Digital input DI33
Use the value of DI33 in the logic rule
(High = TRUE).
[39]
Start command
This event is TRUE if the frequency
converter is started by any means
(either via digital input, fieldbus or
other).
[40]
Drive stopped
This event is TRUE if the frequency
converter is stopped or coasted by any
means (either via digital input, fieldbus
or other).
[41]
Reset Trip
This event is TRUE if the frequency
converter is tripped (but not trip-
locked) and the reset button is
pressed.
[42]
Auto Reset Trip
This event is TRUE if the frequency
converter is tripped (but not trip-
locked) and an Automatic Reset is
issued.
[43]
OK Key
This event is TRUE if the OK key on the
LCP is pressed.
[44]
Reset Key
This event is TRUE if the Reset key on
the LCP is pressed.
[45]
Left Key
This event is TRUE if the Left key on
the LCP is pressed.
[46]
Right Key
This event is TRUE if the Right key on
the LCP is pressed.
[47]
Up Key
This event is TRUE if the Up key on the
LCP is pressed.
Parameter Description
VLT
®
HVAC Drive Programming Guide
MG.11.CB.02 - VLT
®