004
Active Setup
(active Setup)
Value:
Factory Setup (FACTORY SETUP)
[0]
setup 1 (setup 1)
[1]
setup 2 (setup 2)
[2]
Setup 3 (setup 3)
[3]
setup 4 (setup 4)
[4]
Multi Setup (MULTI SETUP)
[5]
Function:
The active parameter Setup is selected here. All pa-
rameters can be programmed in four individual pa-
rameter Setups. Shifts between Setups can be made
in this parameter via a digital input or via serial com-
munication.
Description of choice:
Factory Setup
[0] contains the factory-set parameter
values.
Setup 1-4
[1]-[4] are four individual Setups
which can be selected as required.
Multi Setup
[5] is
used where remote-controlled shifts between the four
Setups via a digital input or via serial communication
is required.
005
Programming Set-up
(EDIT SET-UP)
Value:
Factory Set-up (FACTORY SET-UP)
[0]
Set-up 1 (set-up 1)
[1]
Set-up 2 (set-up 2)
[2]
Set-up 3 (set-up 3)
[3]
Set-up 4 (set-up 4)
[4]
Active Set-up (ACTIVE SET-UP)
[5]
Function:
You can select the desired set-up to program during
operation (this applies both via the control panel and
the serial communication port). For example, it is pos-
sible to program
Set-up 2
[2] while the active set-up is
set to
Set-up 1
[1] in parameter 004
Active Set-up
.
Description of choice:
Factory Set-up
[0] contains the factory-set data and
can be used as a source of data if the other set-ups
are to be reset to a known status.
Set-up 1-4
[1]-[4]
consists of individual set-ups that can be programmed
freely during operation. If
Active Set-up
[5] is selected,
the programming set-up will be equal to parameter 004
Active Set-up
.
NOTE
If data is modified or copied to the active
set-up, the modifications have an imme-
diate effect on the unit's operation.
006
Setup copying
(SETUP COPY)
Value:
No copying (NO COPY)
[0]
Copy to Setup 1 from #
(COPY TO SETUP 1)
[1]
Copy to Setup 2 from #
(COPY TO SETUP 2)
[2]
Copy to Setup 3 from #
(COPY TO SETUP 3)
[3]
Copy to Setup 4 from #
(COPY TO SETUP 4)
[4]
Copy to all Setups from # (copy to all)
[5]
Function:
You can copy from the selected active Setup in pa-
rameter 005
Programming setup
to the selected Setup
or Setups in this parameter.
NOTE
Copying is only possible in Stop (motor
stopped in connection with a stop com-
mand).
Description of choice:
Copying begins when the required copying function
has been selected and the [OK]/[CHANGE DATA] key
has been pushed. The display indicates when copying
is in progress.
VLT
®
2800 Series
= factory setting, () = display text, [] = value for use in communication via serial communication port
34
MG.27.A2.22 - VLT
®
is a registered Danfoss trademark