Pa
r. No.
#
Pa
rame
ter de
script
ion
D
ef
au
lt
va
lue
4-
set-
up
Chang
e
duri
ng
op
er-
ati
on
Conve
r-
sion
inde
x
Type
14
-0* In
ve
rt
er
S
w
it
ch
in
g
14-
00
Swi
tch
in
g Pattern
nu
ll
Al
l s
et
-up
s
TR
U
E
-
Ui
nt
8
14-
01
Sw
itc
hin
g F
requ
en
cy
null
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
14-
03
Ove
rmod
ul
atio
n
[1] On
Al
l set-
up
s
FALSE
-
U
in
t8
14-
04
PW
M R
and
om
[0] Off
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
14
-1* Main
s
On
/Of
f
14-
10
Mains Fa
ilure
[0] No
fu
ncti
on
Al
l s
et
-u
ps
FALSE
-
Ui
nt8
14-
11
Ma
ins Vo
lta
ge at Ma
ins Faul
t
SR
All
set-
up
s
TR
U
E
0
U
int16
14-
12
Funct
ion
at
Mains Imba
la
nc
e
[3
] De
ra
te
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
14
-2* Re
set
Fun
ct
io
n
s
14-
20
Re
set Mod
e
[1
0] Aut
omatic re
set
x 10
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
14-
21
Automatic R
estart
Ti
me
10 s
All
set-
up
s
TR
U
E
0
U
int16
14-
22
Op
era
tio
n Mo
de
[0
] No
rmal
op
er
at
io
n
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
14-
23
Type
co
de
Se
tt
in
g
null
2 se
t-
ups
FALSE
-
U
in
t8
14-
25
Trip De
la
y a
t
Torq
ue
Lim
it
60 s
Al
l s
et
-u
ps
TRU
E
0
Ui
nt8
14-
26
Trip
Del
ay at
I
nve
rter Faul
t
SR
All
set-
up
s
TR
U
E
0
Ui
nt
8
14-
28
Pro
duction Sett
in
gs
[0] No
acti
on
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
14-
29
Servi
ce C
od
e
0 N/A
All
se
t-u
ps
TRUE
0
Int32
14
-3* Cu
rr
en
t Li
mit
Ctr
l.
14-
30
Current Li
m
Ctrl,
P
ro
po
rtio
nal
Gain
100
%
All
set-
up
s
FALSE
0
U
int16
14-
31
Curre
nt Li
m
Ctrl, Int
egra
tio
n Ti
me
0.
020 s
Al
l s
et
-u
ps
FALSE
-3
Ui
nt1
6
14-
32
Current Li
m
Ctrl,
Fil
ter Ti
me
27.
0
ms
Al
l set-
up
s
FALSE
-4
U
int16
14
-4* En
er
gy Opti
misi
ng
14-
40
VT L
evel
66
%
All
se
t-u
ps
FALSE
0
U
in
t8
14-
41
AE
O M
in
imu
m M
agn
et
is
at
io
n
SR
Al
l s
et
-u
ps
TRU
E
0
Ui
nt8
14-
42
Mi
ni
mum AEO
Freq
uency
10 Hz
Al
l set-
up
s
TR
U
E
0
Ui
nt
8
14-
43
Moto
r Cosphi
SR
Al
l s
et
-u
ps
TRU
E
-2
Ui
nt1
6
14
-5* Env
ir
o
nme
n
t
14-
50
RFI
Fil
ter
[1] On
1 set-up
FALSE
-
Ui
nt8
14-
52
Fan Co
ntrol
[0] Auto
Al
l set-
up
s
TR
U
E
-
Ui
nt
8
14-
53
Fa
n M
oni
to
r
[1
] Warning
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
14-
55
Outp
ut
Fi
lte
r
[0
] No Fi
lter
1 set-up
FALSE
-
Ui
nt
8
14-
59
Actu
al
Nu
mb
er
o
f I
nv
erter
Un
its
SR
1 set-up
FALSE
0
Ui
nt8
14
-6* Au
to
Der
ate
14-
60
Funct
ion
at
Ove
r Tempe
rature
[1
] De
ra
te
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
14
-6
1
Funct
ion
at
I
nve
rter O
ver
loa
d
[1
] Der
ate
Al
l se
t-u
ps
TRU
E
-
U
in
t8
14-
62
Inv. Ov
erl
oad Dera
te
Curre
nt
95
%
Al
l s
et
-u
ps
TRU
E
0
Ui
nt1
6
14
-8* Opt
ion
s
14-
80
O
pti
on Supp
lie
d by E
xt
erna
l 2
4V
DC
[0
] No
2 set-up
s
FALSE
-
Ui
nt8
8.3.1
3
Special
Functions 14-*
*
Automation VT Drive FC322
Instruction Manual
8 How to Programme the Frequency Converter
MG.20.U1.22
135
8
Содержание FC322 Series
Страница 6: ...2 Safety Automation VT Drive FC322 Instruction Manual 6 MG 20 U1 22 2 ...
Страница 14: ...4 Mechanical Installation Automation VT Drive FC322 Instruction Manual 14 MG 20 U1 22 4 ...
Страница 103: ...Automation VT Drive FC322 Instruction Manual 8 How to Programme the Frequency Converter MG 20 U1 22 103 8 ...
Страница 154: ...9 Troubleshooting Automation VT Drive FC322 Instruction Manual 154 MG 20 U1 22 9 ...
Страница 163: ...10 Specifications Automation VT Drive FC322 Instruction Manual 10 Specifications MG 20 U1 22 163 10 ...