Ordering type codemodel number frame size F
Description
Pos
Possible choice
Product group
1-3
AutomationDrive FC 302
Drive series
4-6
AutomationDrive FC 302
Power rating
8-10
600–1600 hp [450–1200 kW]
Phases
11
Three phases (T)
AC line voltage
11-
12
T 5: 380–500 V AC
T 7: 525–690 V AC
Enclosure
13-
15
E21: IP 21/ NEMA Type 1
E54: IP 54/ NEMA Type 12
L2X: IP21/NEMA 1 with cabinet light &
IEC 230 V power outlet
L5X: IP54/NEMA 12 with cabinet light &
IEC 230 V power outlet
L2A: IP21/NEMA 1 with cabinet light &
NAM 115 V power outlet
L5A: IP54/NEMA 12 with cabinet light &
NAM 115 V power outlet
H21: IP21 with space heater and ther-
mostat
H54: IP54 with space heater and ther-
mostat
R2X: IP21/NEMA1 with space heater,
thermostat, light & IEC 230 V outlet
R5X: IP54/NEMA12 with space heater,
thermostat, light & IEC 230 V outlet
R2A: IP21/NEMA1 with space heater,
thermostat, light, & NAM 115 V outlet
R5A: IP54/NEMA12 with space heater,
thermostat, light, & NAM 115 V outlet
RFI filter
16-
17
H2: RFI filter, class A2 (standard)
H4: RFI filter, class A1
2, 3)
HE: RCD with Class A2 RFI filter
2)
HF: RCD with class A1 RFI filter
2, 3)
HG: IRM with Class A2 RFI filter
2)
HH: IRM with class A1 RFI filter
2, 3)
HJ: NAMUR terminals and class A2 RFI
filter
1)
HK: NAMUR terminals with class A1 RFI
filter
1, 2, 3)
HL: RCD with NAMUR terminals and
class A2 RFI filter
1, 2)
HM: RCD with NAMUR terminals and
class A1 RFI filter
1, 2, 3)
HN: IRM with NAMUR terminals and
class A2 RFI filter
1, 2)
HP: IRM with NAMUR terminals and
class A1 RFI filter
1, 2, 3)
Brake
18
B: Brake IGBT mounted
X: No brake IGBT
R: Regeneration terminals
M: IEC Emergency stop pushbutton
(with Pilz safety relay)
4)
N: IEC Emergency stop pushbutton
with brake IGBT and brake terminals
4)
P: IEC Emergency stop pushbutton with
regeneration terminals
4)
Display
19
G: Graphical Local Control Panel LCP
Coating PCB
20
C: Coated PCB
Description
Pos
Possible choice
Line power op-
tion
21
X: No AC line power option
3
2)
: Line power disconnect and fuse
5
2)
: Line power disconnect, fuse and
load sharing
7: Fuse
A: Fuse and load sharing
D: Load sharing
E: Line power disconnect, contactor &
fuses2)
F: Line power circuit breaker, contactor
& fuses 2)
G: Line power disconnect, contactor,
load sharing terminals & fuses2)
H: Line power circuit breaker, contac-
tor, load sharing terminals & fuses2)
J: Line power circuit breaker & fuses 2)
K: Line power circuit breaker, load shar-
ing terminals & fuses 2)
Power Terminals
& Motor Starters
22
X: No option
E 30 A, fuse-protected power terminals
F: 30A, fuse-protected power terminals
& 2.5–4 A manual motor starter
G: 30A, fuse-protected power terminals
& 4–6.3 A manual motor starter
H: 30A, fuse-protected power terminals
& 6.3–10 A manual motor starter
J: 30A, fuse-protected power terminals
& 10–16 A manual motor starter
K: Two 2.5–4 A manual motor starters
L: Two 4–6.3 A manual motor starters
M: Two 6.3–10 A manual motor starters
N: Two 10–16 A manual motor starters
Auxiliary 24 V
Supply & Exter-
nal Temperature
Monitoring
23
X: No option
H: 5A, 24 V power supply (customer
use)
J: External temperature monitoring
G: 5A, 24 V power supply (customer
use) & external temperature monitoring
Software release 24-
27
Current software
Software lan-
guage
28
1) MCB 113 Extended Relay Card and MCB 112 PTC Thermistor Card
required for NAMUR terminals
2) F3 and F4 frames only
3) 380–480/500 V only
4) Requires contactor
5 How to Order
FC 300 Design Guide
5-4
MG.33.BC.22 - VLT
®
is a registered Danfoss trademark
5