Z-Trak2 3D Profiler Sensors
Using Z-Expert
•
53
Figure 20. (Left) Display showing a highly saturated profile. (Right) Same profile with decreased laser
intensity and profile exposure time.
Optimizing profile rate
Use following guidelines to acquire profiles at the maximum speed:
•
In the
Data Output
category, change the number of
Profiles Per Scan
to 200 profiles or
more.
•
In the
Format
subcategory, set the
3D Data Type
output format to
UniformX Z
or to
XZ
.
•
In the
GigE Vision Transport Layer
category, verify that the
Device Link Speed
value is
1000, 2500, or 5000 Mbps or higher (according to model). This is the speed negotiated by the
network interface. The value is read-only.
•
Verify that the
Packet Size
value is above 1500 bytes, ideally 4000 or 9000 bytes, which
indicates that jumbo packets are used. To enable jumbo packets, you may use the Sapera LT
Network Configuration tool (
Jumbo Frames
on the NIC Information page).