98
•
Z-Trak2 features reference
Z-Trak2 3D Profiler Sensors
Display Name
Feature & Values
Description
Version
& View
Profile Trigger
LineStart Counts the number of Profile Trigger events.
Valid Profile Trigger
ValidLineTrigger Counts the number of Valid Profile Triggers.
Rejected Profile(s)
Trigger
InvalidLineTrigger Counts the number of Rejected Profile(s) Trigger.
Line 3
Line3 Counts the number of transitions on Line 3 (based on
the counterIncrementalLineActivation feature setting)
Line 4
Line4 Counts the number of transitions on Line 4 (based on
the counterIncrementalLineActivation feature setting)
Internal Clock
InternalClock The internal clock increments the counter value.
Timer 1 End
Timer1End Counts the number of Timer 1 End events.
Counter Incremental Line
Activation
counterIncrementalLineActivation
Selects the counter signal activation mode. The
counter increments on the specified signal edge or
level.
1.00
Expert
DFNC
Rising Edge
RisingEdge Increment the counter on the rising edge of the
selected I/O Line.
Falling Edge
FallingEdge Increment the counter on the falling edge of the
selected I/O Line.
Any Edge
AnyEdge Increment the counter on the falling or rising edge of
the selected I/O Line.
Counter Reset Source
counterResetSource
Selects the signal source to reset the counter. After a
reset the counter waits for the next countStartSource
signal or event.
1.00
Expert
DFNC
Reset Cmd
Off Reset on reception of the Reset Icommand.
Acquisition Start
AcquisitionStart Reset on reception of the Acquisition Start.
Acquisition End
AcquisitionEnd Reset on reception of the Acquisition End
Exposure Start
ExposureStart Reset on reception of the Exposure Start event.
Exposure End
ExposureEnd Reset on reception of the Exposure End event.
Readout Start
ReadoutStart Reset the counter on the reception of the Readout
Start event.
Readout End
ReadoutEnd Reset the counter on the reception of the Readout
End event.
Profile Trigger
LineStart Reset on reception of the Profile Trigger.
Valid Profile Trigger
ValidLineTrigger Reset on reception of the Valid Profile Trigger.
Rejected Profile Trigger
InvalidLineTrigger Reset on reception of the Invalid Profile Trigger.
Line 3
Line3 Reset counter on the specified transition on line 3.
Line 4
Line4 Reset counter on the specified transition on line 4.
Timer 1 End
Timer1End Reset on reception of the Timer End.
Counter 1 End
Counter1End Reset on the reception of the Counter 1 end.
Counter Reset Input Line
Activation
counterResetLineActivation
Specify the edge transition on the selected line that
will reset the selected counter.
1.00
Expert
DFNC
Rising Edge
RisingEdge Reset counter on rising edge of the selected signal.
Falling Edge
FallingEdge Reset counter on falling edge of the selected signal.
Any Edge
AnyEdge Reset counter on the falling or rising edge of the
selected signal
Counter Duration
counterDuration
Sets the terminal value of the counter; when the
"Counter Value" reaches this value a CounterEnd
event is generated.
1.00
Expert
DFNC
Counter Value
counterValue
Read the current value of the selected counter.
1.00
Expert
DFNC
Counter Value At Reset
counterValueAtReset
Reads the counter value of the selected counter when
it was reset by a trigger or by an explicit Counter
Reset command.
1.00
Expert
DFNC