Z-Trak2 3D Profiler Sensors
Z-Trak2 features reference
•
99
Display Name
Feature & Values
Description
Version
& View
Counter Reset
counterReset
Resets the selected counter to zero. The counter
starts immediately after the reset. To temporarily
disable the counter, set the Counter Event Source
feature to Off.
1.00
Expert
DFNC
Timer Selector
timerSelector
Selects which timer to configure.
1.00
Expert
DFNC
Timer 1
Timer1 Timer 1 selected
Timer Mode
timerMode
Select the Timer mode. The selected Timer is Active
or Disabled. When Disabled, the Timer can be
configured.
1.00
Expert
DFNC
Off
Off The selected Timer is Disabled.
Active
Active The selected Timer is Enabled.
Timer Status
timerStatus
Returns the current state of the timer.
1.00
Expert
DFNC
Timer Idle
TimerIdle The timer is idle. The counterStartSource feature is
set to off.
Timer Trigger Wait
TimerTriggerWait The timer is waiting for a start trigger.
Timer Active
TimerActive The timer is counting for the specified duration.
Timer Completed
TimerCompleted The timer reached the timerDuration count.
Timer Start Source
timerStartSource
Select the trigger source to start the timer.
1.00
Expert
DFNC
TimerReset Cmd
Off Starts with the reception of the TimerReset
Icommand.
Acquisition Start
AcquisitionStart Start Timer on Acquisition Start event.
Acquisition End
AcquisitionEnd Start Timer on Acquisition End event
Exposure Start
ExposureStart Start Timer on Exposure Start event.
Exposure End
ExposureEnd Start Timer on Exposure End event.
Readout Start
ReadoutEnd Start Timer on Readout Start event.
Readout End
ReadoutStart Start Timer on Readout End event.
Profile Trigger
LineStart Start Timer on Profile Trigger event.
Valid Profile Trigger
ValidLineTrigger Start Timer on Valid Profile Trigger event.
Multi Sensor Sync
MultiSensorSync Multi Sensor Sync
Line 3
Line3 Start Timer on a transition of I/O Line 3 event.
Line 4
Line4 Start Timer on a transition of I/O Line 4 event.
Timer 1 End
Timer1End Start Timer on Timer End event.
Counter 1 End
Counter1End Start Timer on Counter 1 End event.
Timer Line Activation
timerStartLineActivation
Select the trigger activation mode which starts the
timer.
1.00
Expert
DFNC
Rising Edge
RisingEdge Starts counter on rising edge of the selected signal.
Falling Edge
FallingEdge Starts counter on falling edge of the selected signal.
Any Edge
AnyEdge Starts counter on the falling or rising edge of the
selected signal.
Timer Duration
timerDuration
Sets the duration (in microseconds) of the timer
pulse.
1.00
Expert
DFNC
Timer Value
timerValue
Reads the current value (in microseconds) of the
selected timer.
1.00
Expert
DFNC
Timer Reset
timerReset
Resets the timer to 0.
1.00
Expert
DFNC