118
•
Technical specifications
Z-Trak2 3D Profiler Sensors
Figure 28. Pinout details for the emergency safety switch.
The E-STOP safety feature is enabled by default. However, IF PERMITTED BY LOCAL
REGULATIONS, it can be disabled in the Z-Trak2 configuration.
Power over Ethernet (PoE+) support
The Z-Trak2 profiler requires an IEEE 802.3at PoE type 2 (PoE+)
—
or better
—
power source when
using a PoE Ethernet switch or injector, else a separate external power source connected to the I/O
connector is required.
To use PoE, the network setup requires a powered computer NIC supporting PoE, a PoE capable
Ethernet switch, or an Ethernet power injector. Using PoE in the context of 5 GigE bandwidth (S-
Series) generates heat. See Temperature management.
Connect power via the I/O connector or PoE, but not both.
Even though Z-Trak2 has protection, differences in ground levels may cause operational issues or
electrical faults.
When using PoE, the Z-Trak2 I/O pins 7/6 (profiler power/ground) must not be
connected to I/O pin 17 (input signal common ground).
PoE+ power requirements (PoE supply)
PoE DC Operating Characteristics
PoE Injector Voltage
Current Consumed (typical)
PoE = 57 V DC
TBD