Z-Trak2 3D Profiler Sensors
Z-Trak2 features reference
•
97
Display Name
Feature & Values
Description
Version
& View
Counter Status
counterStatus
Returns the current state of the counter.
1.00
Expert
DFNC
Counter Idle
CounterIdle The counter is idle.
The counterStartSource feature is set to off.
Counter Trigger Wait
CounterTriggerWait The counter is waiting for a start trigger.
Counter Active
CounterActive The counter is counting for the specified duration.
Counter Completed
CounterCompleted The counter reached the CounterDuration count.
Counter Overflow
CounterOverflow The counter reached its maximum possible count.
Counter Start Source
counterStartSource
Select the counter start source. Counter increments
from 0 to the value of the counterDuration feature.
1.00
Expert
DFNC
Off
Off Counter is stopped.
Acquisition Start
AcquisitionStart Counter starts on the reception of the Acquisition
Start event.
Acquisition End
AcquisitionEnd Counter starts on the reception of the Acquisition End
event.
Exposure Start
ExposureStart Counter starts on the reception of the Exposure Start
event
Exposure End
ExposureEnd Counter starts on the reception of the Exposure End
event.
Readout Start
ReadoutStart Counter starts on the reception of the Readout Start
event.
Readout End
ReadoutEnd Counter starts on the reception of the Readout End
event.
Profile Start
LineStart Counter starts on the reception of the Profile Trigger
event.
Valid Profile Trigger
ValidLineTrigger Counter starts on the reception of the Valid Profile
Trigger.
Rejected Profile Trigger
InvalidLineTrigger Counter starts on the reception of the Invalid Profile
Trigger.
Multi Sensor Sync
MultiSensorSync The Multi Sensor Sync signal will start the counter.
Line 3
Line3 Counter starts on the specified transitions on Line 3
Line 4
Line4 Counter starts on the specified transitions on Line 4
Timer 1 End
Timer1End Counter starts on the reception of the Timer 1 End
event.
Counter 1 End
Counter1End Counter starts on the reception of the Counter 1 End
event.
Counter Start Line
Activation
counterStartLineActivation
Selects the activation mode of the input line trigger
which starts the counter. This is only applicable when
the counterStartSource feature selects a physical
Line.
1.00
Expert
DFNC
Rising Edge
RisingEdge Starts counting on rising edge of the selected Line.
Falling Edge
FallingEdge Starts counting on falling edge of the selected Line.
Any Edge
AnyEdge Starts counting on the falling or rising edge of the
selected Line.
Counter Incremental
Source
counterIncrementalSource
Select the event source which increments the
counter.
1.00
Expert
DFNC
Off
Off Counter is stopped.
Acquisition Start
AcquisitionStart Counts the number of Acquisition Start events.
Acquisition End
AcquisitionEnd Counts the number of Acquisition End events.
Exposure Start
ExposureStart Counts the number of Exposure Start events.
Exposure End
ExposureEnd Counts the number of Exposure End events.
Readout Start
ReadoutStart Counts the number of Readout Start events.
Readout End
ReadoutEnd Counts the number of Readout End events.