100
•
Z-Trak2 features reference
Z-Trak2 3D Profiler Sensors
IEEE1588 category
The IEEE1588 controls as shown by Z-Expert, has parameters used to configure the Precision Time
Protocol function.
IEEE1588 features
Display Name
Feature & Values
Description
Version
& View
PTP Mode
ptpMode
Specifies the PTP (IEEE-1588: Precision Time
Protocol) operating mode implemented. If
multiSensorSyncMode is not Off, ptpMode
cannot be put to Off.
1.00
Expert
DFNC
Off
Off PTP is disabled on the device.
Automatic
Automatic PTP is enabled on the device. The camera can
become a Master or Slave device. The Master
device is automatically determined as per IEEE-
1588.
Slave
Slave Device will operate in PTP slave-only mode.