68
•
Z-Trak2 features reference
Z-Trak2 3D Profiler Sensors
Display Name
Feature & Values
Description
Device
Version
& View
Laser Safety
laserSafety
Determines if the laser safety is applied through an
external E-stop pin or bypassed internally using this
feature.
1.00
DFNC
Guru
External
External
The laser can be turned on if power is applied to the E-
Stop pin of the auxiliary connector.
Internal
Internal
The laser can be turned on using the Laser Activation
feature. Power does not need to be applied to the E-
Stop pin.
Laser Power
laserPower
User set laser power setting for when the feature
laserControlMode=Manual.
1.00
DFNC
Beginner
Profile Average
Reflectance
profileAvgReflectance
Reads the average reflectance of the last profile.
1.00
DFNC
Expert
Laser Automatic Target
Average Reflectance
laserAutoTargetAvgReflectance
User set reflectance value used as the target for when
the feature laserControlMode=Auto.
1.00
DFNC
Expert
Laser Automatic Power
laserAutoPower
Reads the current laser power setting when the
feature laserControlMode=Auto.
1.00
DFNC
Expert
Laser Automatic
Minimum Power
laserAutoMinPower
Laser Automatic Minimum Power.
1.00
DFNC
Expert
Laser Automatic
Maximum Power
laserAutoMaxPower
Laser Automatic Maximum Power.
1.00
DFNC
Expert
Profile Rate (Hz)
profileRate
Specifies the profile rate of the sensor, in Hz.
1.00
DFNC
Beginner
Profile Exposure Time
(in us)
ExposureTime
Sets the exposure time (in microseconds) when the
Exposure Mode feature is set to Timed.
1.00
DFNC
Beginner
Reflectance Threshold
peakDetectorReflectanceThreshold
Value which identifies the minimum reflectance a peak
must have to be considered.
1.00
DFNC
Expert
HDR Response Mode
hdrResponseMode
Sets the state of the multislope response mechanism
on the sensor.
1.00
DFNC
Expert
Off
Off
Disables the hdrResponseMode feature.
One Knee Point, Mid
OneKneeMid
One Knee Point, Mid Position (~70%).
One Knee Point, High
OneKneeHigh
One Knee Point, High Position (~90%).
HDR Response Factor
hdrResponseFactor
HDR Response Factor.
1.00
DFNC
Expert
FIR Size
firSize
Sets the size of the FIR
(finite impulse response)
.
1.00
DFNC
Guru
11
fir11
FIR size 11.
9
fir9
FIR size 9.
7
fir7
FIR size 7.
5
fir5
FIR size 5.
Gamma Correction
gammaCorrection
Sets the gamma correction factor (i.e. inverse
gamma). The gamma correction is applied as an
exponent to the original pixel value. (Default value: 1,
max value: 1, min value: 0.001, increments: 0.001)
1.00
DFNC
Expert