SiME341909EA
Troubleshooting by Error Code
Part 6 Service Diagnosis
155
L9 - 01
Compressor M1C startup error (Master)
Refer to the
L9
flowchart and make a diagnosis
of the relevant compressor based
on the Error code shown to the left.
L9 - 05
Compressor M1C startup error (Slave 1)
L9 - 06
Compressor M1C startup error (Slave 2)
L9 - 10
Compressor M2C startup error (Master)
L9 - 11
Compressor M2C startup error (Slave 1)
L9 - 12
Compressor M2C startup error (Slave 2)
L9 - 13
Compressor M1C output open phase (Master)
L9 - 14
Compressor M1C output open phase (Slave 1)
L9 - 15
Compressor M1C output open phase (Slave 2)
L9 - 16
Compressor M2C output open phase (Master)
L9 - 17
Compressor M2C output open phase (Slave 1)
L9 - 18
Compressor M2C output open phase (Slave 2)
LC - 14
Transmission error
(Between outdoor units, inverter PCB 1) (Master)
Refer to the
LC
flowchart and make a diagnosis based
on the Error code shown to the left.
LC - 15
Transmission error
(Between outdoor units, inverter PCB 1) (Slave 1)
LC - 16
Transmission error
(Between outdoor units, inverter PCB 1) (Slave 2)
LC - 19
Transmission error
(Between outdoor units, fan PCB 1) (Master)
LC - 20
Transmission error
(Between outdoor units, fan PCB 1) (Slave 1)
LC - 21
Transmission error
(Between outdoor units, fan PCB 1) (Slave 2)
LC - 24
Transmission error
(Between outdoor units, fan PCB 2) (Master)
LC - 25
Transmission error
(Between outdoor units, fan PCB 2) (Slave 1)
LC - 26
Transmission error
(Between outdoor units, fan PCB 2) (Slave 2)
LC - 30
Transmission error
(Between outdoor units, inverter PCB 2) (Master)
LC - 31
Transmission error
(Between outdoor units, inverter PCB 2) (Slave 1)
LC - 32
Transmission error
(Between outdoor units, inverter PCB 2) (Slave 2)
P1 - 01
Unbalanced power supply voltage (Master)
Refer to the
P1
flowchart and make a diagnosis based
on the Error code shown to the left.
P1 - 02
Unbalanced power supply voltage (Slave 1)
P1 - 03
Unbalanced power supply voltage (Slave 2)
P1 - 07
Inverter 2 power supply unbalanced voltage (Master)
P1 - 08
Inverter 2 power supply unbalanced voltage (Slave 1)
P1 - 09
Inverter 2 power supply unbalanced voltage (Slave 2)
Error code
Troubleshooting
Description of error
Diagnosis
Содержание VRV X RXQ6-48ANR Series
Страница 1: ...Service Manual Cooling Only 50 60 Hz RXQ6 48A N R Series SiME341909EA...
Страница 287: ...SiME341909EA Part 7 Appendix 281 1 Wiring Diagrams 282 1 1 Outdoor Unit 282 1 2 Indoor Unit 285 Part 7 Appendix...
Страница 288: ...Wiring Diagrams SiME341909EA 282 Part 7 Appendix 1 Wiring Diagrams 1 1 Outdoor Unit RXQ6 8ARYFK 3D124186A...
Страница 289: ...SiME341909EA Wiring Diagrams Part 7 Appendix 283 RXQ10 12ARYFK 2D124184...
Страница 290: ...Wiring Diagrams SiME341909EA 284 Part 7 Appendix RXQ14 16ARYFK 2D124183...
Страница 292: ...Wiring Diagrams SiME341909EA 286 Part 7 Appendix BYCQ125EASF Auto Grille Panel for FXFSQ AR 3D108035...
Страница 295: ...SiME341909EA Wiring Diagrams Part 7 Appendix 289 FXMQ40 50 63 80 100ARV1 3D127112 04 59...
Страница 296: ...Wiring Diagrams SiME341909EA 290 Part 7 Appendix 1 2 4 Wall Mounted Type FXAQ20 25 32 40 50 63ARVM 3D118250D...