Wall Mounted and LSP Duct Type Functions
SiSG121917E
51
Part 4 Functions and Control
1.9 ECONO Operation
Applicable
Models
CTKS25/35/50/60/71TVMG
CTKB25/35/50/60TVMG
Outline
ECONO operation reduces the maximum operating current and the power consumption.
This operation is particularly convenient for energy-saving. It is also a major bonus when
breaker capacity does not allow the use of multiple electrical devices and air conditioners.
It can be easily activated by pressing
Econo/Quiet
button on the wireless remote controller.
Details
When this function is activated, the maximum capacity also decreases.
The remote controller can send the ECONO command when the unit is in cooling or dry
operation. This function can only be set when the unit is running. To cancel the ECONO
operation, press
Econo/Quiet
button several times until the ECONO symbol disappears.
This function and POWERFUL operation cannot be used at the same time. The latest
command has the priority.
1.10 HOME LEAVE Operation
Applicable
Models
FDKS25/35EAVMB
FDKS25/35CAVMB
FDKS50/60CVMB
Outline
HOME LEAVE operation is a function that allows you to record your preferred set temperature
and airflow rate. You can start your preferred operation mode simply by pressing
HOME LEAVE
button on the remote controller.
Details
1. Function Start
The function starts when
HOME LEAVE
button is pressed in cooling operation (including
POWERFUL operation), or while the operation is stopped. If
HOME LEAVE
button is
pressed in POWERFUL operation, the POWERFUL operation is canceled and the HOME
LEAVE function becomes effective.
HOME LEAVE
button is ineffective in dry operation and fan operation.
2. Function Details
A mark representing HOME LEAVE is indicated on the display of the remote controller. The
indoor unit is operated according to the set temperature and airflow rate for HOME LEAVE
which were recorded in the memory of the remote controller.
The LED (red) of indoor unit representing HOME LEAVE lights up. It goes out when the
operation is stopped.
ECONO operation
(R22012)
Normal operation
Maximum during normal operation
Maximum during ECONO operation
Time
Power
consumption
and current
Содержание FDMR50TVMG
Страница 185: ...SiSG121917E Check Part 6 Service Diagnosis 180 50 65 80 class 90 class V U DC DC R22378 W R21130 W V U DCP2 DCM2 ...
Страница 212: ...Piping Diagrams SiSG121917E 207 Part 8 Appendix MKS65TVMG MKB65TVMG MKS80TVMG 3D103941A 3D103942A ...
Страница 213: ...SiSG121917E Piping Diagrams Part 8 Appendix 208 MKS90TVMG 3D104086 ...
Страница 223: ...SiSG121917E Operation Limit Part 8 Appendix 218 3 Operation Limit MKS50 65 80 90TVMG MKB50 65TVMG 4D078793B ...