Troubleshooting for Outdoor Unit
SiSG121917E
149
Part 6 Service Diagnosis
Note
Reference
Reference
Reference
Troubleshooting
OL (Q1L) activating temperature: 130°C
OL (Q1L) recovery temperature: 95°C
Check No.01
Refer to P.169
Check No.12
Refer to P.172
Check No.14
Refer to P.173
Caution
YES
NG
NO
OK
NG
YES
NO
Disconnect the connector S40
from the PCB.
Disconnect the 2 terminals of
the OL (Q1L).
Resistance
∞
Resistance
∞
Nearly 0
Ω
Nearly 0
Ω
Insert the thermistor in
position.
Replace the discharge pipe
thermistor.
Replace the electronic
expansion valve or the coil.
Discharge
pipe thermistor
disconnected?
Check No. 12
Check the electronic
expansion valve.
Replace the OL (Q1L).
Replace the OL harness.
Connect the connector S40
properly.
Is the connector
S40 properly connected?
Check No. 01
Check the discharge pipe
thermistor.
Check
the resistance
between the 2 terminals on
connector S40.
Check the
resistance between the
2 terminals of the OL
(Q1L).
(R23383)
OK
NG
OK
∗
Refrigerant shortage
∗
Water mixed
∗
Stop valve
Refer to the refrigerant line
check procedure.
Replace the outdoor unit
PCB (main PCB).
Check No. 14
Check the refrigerant
line.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Содержание FDMR50TVMG
Страница 185: ...SiSG121917E Check Part 6 Service Diagnosis 180 50 65 80 class 90 class V U DC DC R22378 W R21130 W V U DCP2 DCM2 ...
Страница 212: ...Piping Diagrams SiSG121917E 207 Part 8 Appendix MKS65TVMG MKB65TVMG MKS80TVMG 3D103941A 3D103942A ...
Страница 213: ...SiSG121917E Piping Diagrams Part 8 Appendix 208 MKS90TVMG 3D104086 ...
Страница 223: ...SiSG121917E Operation Limit Part 8 Appendix 218 3 Operation Limit MKS50 65 80 90TVMG MKB50 65TVMG 4D078793B ...