SiSG121917E
Service Diagnosis
Part 6 Service Diagnosis
108
3.1.2 Method 2
1. Press the center of
Temp
button and
Mode
button at the same time.
R6000648
5C
is displayed on the LCD.
R6000109
2. Select
5C
(service check) with
Temp
or
Temp
button.
3. Press
Mode
button to enter the service check mode.
R6000649
The left-side number blinks.
R6000111
4. Press
Temp
or
Temp
button and change the number until you hear the two
consecutive beeps or the long beep.
R6000650
5. Diagnose by the sound.
Beep: The left-side number does not correspond with the error code.
Two consecutive beeps: The left-side number corresponds with the error code but the
right-side number does not.
Содержание FDMR50TVMG
Страница 185: ...SiSG121917E Check Part 6 Service Diagnosis 180 50 65 80 class 90 class V U DC DC R22378 W R21130 W V U DCP2 DCM2 ...
Страница 212: ...Piping Diagrams SiSG121917E 207 Part 8 Appendix MKS65TVMG MKB65TVMG MKS80TVMG 3D103941A 3D103942A ...
Страница 213: ...SiSG121917E Piping Diagrams Part 8 Appendix 208 MKS90TVMG 3D104086 ...
Страница 223: ...SiSG121917E Operation Limit Part 8 Appendix 218 3 Operation Limit MKS50 65 80 90TVMG MKB50 65TVMG 4D078793B ...