List of Functions
SiAU18-715
2
List of Functions
1. List of
Functions
1.1
Cooling Only
Category
Functions
RM
K
S
112/
1
40/
160E
V
1
A
Category
Functions
RM
K
S
112/
1
40/
160E
V
1
A
Basic
Function
Inverter (with Inverter Power Control)
{
Health &
Clean
Air Purifying Filter
—
Operation Limit for Cooling (°CDB)
–5
~
46
Photocatalytic Deodorizing Filter
—
Operation Limit for Heating (°CWB)
—
Air Purifying Filter with Photocatalytic
Deodorizing Function
—
PAM Control
—
Titanium Apatite Photocatalytic
Air-Purifying Filter
—
Compressor
Oval Scroll Compressor
{
Longlife Filter (Option)
—
Swing Compressor
—
Mold Proof Air Filter
—
Rotary Compressor
—
Wipe-clean Flat Panel
—
Reluctance DC Motor
{
Washable Grille
—
Comfortable
Airflow
Power-Airflow Flap
—
Filter Cleaning Indicator
—
Power-Airflow Dual Flaps
—
Mold Proof Operation
—
Power-Airflow Diffuser
—
Heating Dry Operation
—
Wide-Angle Louvers
—
Good-Sleep Cooling Operation
—
Vertical Auto-Swing (Up and Down)
—
Timer
Weekly Timer
—
24-Hour On/Off Timer
—
72-Hour On/Off Timer
—
Horizontal Auto-Swing (Right and Left)
—
Night Set Mode
—
3-D Airflow
—
Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure)
—
Comfort Airflow Mode
—
Self-Diagnosis (Digital, LED) Display
{
3-Step Airflow (H/P Only)
—
Wiring-Error Check
—
Comfort
Control
Auto Fan Speed
—
Automatic Test Operation
{
Indoor Unit Quiet Operation
—
Memory Function
{
Night Quiet Mode (Automatic)
{
Anticorrosion Treatment of Outdoor
Heat Exchanger
{
Outdoor Unit Quiet Operation (Manual)
{
Flexibility
Multi-Split / Split Type Compatible
Indoor Unit
—
Intelligent Eye
—
Flexible Voltage Correspondence
—
Quick Warming Function
—
High Ceiling Application
—
Hot-Start Function
—
Chargeless
—
Automatic Defrosting
—
Either Side Drain (Right or Left)
—
Operation
Automatic Operation
—
Power-Selection
—
Programme Dry Function
—
Remote
Control
5-Rooms Centralized Controller
(Option)
—
Fan Only
—
Remote Control Adaptor
(Normal Open-Pulse Contact) (Option)
—
Lifestyle
Convenience
New Powerful Operation
(Non-Inverter)
—
Remote Control Adaptor
(Normal Open Contact) (Option)
—
Inverter Powerful Operation
—
Dlll-NET Compatible (Adaptor) (Option)
—
Priority-Room Setting
—
Remote
Controller
Wireless
—
Cooling / Heating Mode Lock
—
Wired
—
Home Leave Operation
—
ECONO Mode
—
Indoor Unit On/Off Switch
—
Signal Reception Indicator
—
Temperature Display
—
Another Room Operation
—
Note:
{
: Holding Functions
— : No Functions
Содержание E Series
Страница 1: ...SiAU18 715 Applied Models Super Multi Plus Cooling Only Super Multi Plus Heat Pump E Series ...
Страница 26: ...SiAU18 715 Specifications 13 Part 2 Specifications 1 Specifications 14 1 1 Cooling Only 14 1 2 Heat Pump 23 ...
Страница 87: ...Refrigerant Flow for Each Operation Mode SiAU18 715 74 Refrigerant Circuit ...
Страница 139: ...Indoor Unit SkyAir Models SiAU18 715 126 Function ...
Страница 177: ...Test Operation and Field Setting for RA Indoor Unit SiAU18 715 164 Test Operation ...
Страница 299: ...Instruction SiAU18 715 286 Operation Manual 2 6 Ceiling Suspended Type ...
Страница 326: ...SiAU18 715 Service Check Function Troubleshooting 313 ...
Страница 423: ...Method of Replacing The Inverter s Power Transistors Modules SiAU18 715 410 Troubleshooting ...
Страница 443: ...Wiring Diagrams SiAU18 715 430 Appendix ...
Страница 449: ...SiAU18 715 vi Index ...