SiAU18-715
Instruction
Operation Manual
271
Press the AIR FLOW DIRECTION ADJUST
button to select the air direction as shown
below.
The AIR FLOW FLAP display
swings as shown below and
the air flow direction continu-
ously varies. (Automatic swing
setting)
Press AIR FLOW DIRECTION
ADJUST button to select the air
direction of your choice.
The AIR FLOW FLAP display
stops swinging and the air flow
direction is fixed (Fixed air flow
direction setting).
MOVEMENT OF THE AIR FLOW FLAP
For the following conditions, micro computer con-
trols the air flow direction so it may be different from
the display.
Operation mode includes automatic operation.
Operate in the following order.
•
The timer is operated in the following two ways.
•
Programming the stop time (
) .... The sys-
tem stops
operating after the set time has elapsed.
•
Programming the start time (
) .... The sys-
tem starts
operating after the set time has elapsed.
•
The timer can be programmed a maximum of
72 hours.
•
The start and the stop time can be simultaneously
programmed.
Operation
mode
Cooling
Heating
Operation
condition
•
When room
temperature is
lower than the
set temperature
•
When operating
continuously at
horizontal air
flow direction
•
When room
temperature is
higher than the
set temperature
•
At defrost opera-
tion
PROGRAM TIMER OPERATION
swing
TIMER MODE START/STOP
Press the TIMER MODE START/STOP button
several times and select the mode on the
display.
The display flashes.
For setting the timer stop .... “
”
For setting the timer start .... “
”
PROGRAMMING TIME
Press the PROGRAMMING TIME button and
set the time for stopping or starting the sys-
tem.
When this button is pressed, the time
advances by 1 hour.
When this button is pressed, the time
goes backward by 1 hour.
TIMER ON/OFF
Press the TIMER ON/OFF button.
The timer setting procedure ends.
The display “
or
” changes from flash-
ing light to a constant light.
Refer to figure 4 on page [1]
NOTE
•
When setting the timer Off and On at the same
time, repeat the above procedure from
to
once again.
When the timer is programmed to stop the system
after 3 hours and start the system after 4 hours, the
system will stop after 3 hours and then 1 hour later
the system will start.
•
After the timer is programmed, the display shows
the remaining time.
•
Press the TIMER ON/OFF button once again to
cancel programming. The display vanishes.
Observe the following precautions to ensure the
system operates.
•
Adjust the room temperature properly for a com-
fortable environment. Avoid excessive heating or
cooling.
•
Prevent direct sunlight from entering a room dur-
ing cooling operation by using curtains or blinds.
7. OPTIMUM OPERATION
1
2
3
1
3
Содержание E Series
Страница 1: ...SiAU18 715 Applied Models Super Multi Plus Cooling Only Super Multi Plus Heat Pump E Series ...
Страница 26: ...SiAU18 715 Specifications 13 Part 2 Specifications 1 Specifications 14 1 1 Cooling Only 14 1 2 Heat Pump 23 ...
Страница 87: ...Refrigerant Flow for Each Operation Mode SiAU18 715 74 Refrigerant Circuit ...
Страница 139: ...Indoor Unit SkyAir Models SiAU18 715 126 Function ...
Страница 177: ...Test Operation and Field Setting for RA Indoor Unit SiAU18 715 164 Test Operation ...
Страница 299: ...Instruction SiAU18 715 286 Operation Manual 2 6 Ceiling Suspended Type ...
Страница 326: ...SiAU18 715 Service Check Function Troubleshooting 313 ...
Страница 423: ...Method of Replacing The Inverter s Power Transistors Modules SiAU18 715 410 Troubleshooting ...
Страница 443: ...Wiring Diagrams SiAU18 715 430 Appendix ...
Страница 449: ...SiAU18 715 vi Index ...