SiAU18-715
Instruction
Operation Manual
295
HOW TO CLEAN THE AIR FILTER
Clean the air filter when the display shows “ ”
(TIME TO CLEAN AIR FILTER).
It will display that it will operate for a set amount of
time.
Increase the frequency of cleaning if the unit is
installed in a room where the air is extremely con-
taminated.
If the dirt becomes impossible to clean, change the
air filter (Air filter for exchange is optional).
1. Open the suction grille.
Slide both knobs simultaneously as shown and
then pull them downward.
(Do the same procedure for closing.)
(Refer to Fig. 2)
2. Remove the air filters.
Push the 2 tabs up, and slowly lower the grille.
(Refer to Fig. 3)
3. Clean the air filter.
Use vacuum cleaner
A)
or wash the air filter with
water
B).
A)
Using a vacuum cleaner
tab
clip
Fig. 3
Fig. 4
Fig. 5
B)
Washing with water
When the air filter is very dirty, use soft brush
and neutral detergent.
Remove water and dry in the shade.
NOTE
• Do not wash the air conditioner with hot water of
more than 50˚C, as doing so may result in discol-
oration and/or deformation.
• Do not expose it to fire, as doing so may result in
burning.
4. Fix the air filter.
Set the hatch of the air filter to the fook of the
suction grille, and fix the air filter.
(Refer to Fig. 5)
5. Close the suction grille.
Refer to item No. 1.
6. After turning on the power, press FILTER
SIGN RESET BUTTON.
The “TIME TO CLEAN AIR FILTER” display van-
ishes.
HOW TO CLEAN AIR OUTLET AND OUTSIDE
PANELS
• Clean with soft cloth.
• When it is difficult to remove stains, use water or
neutral detergent.
NOTE
• Do not use gasoline, benzene, thinner, polishing
powder, liquid insecticide. It may cause discolor-
ing or warping.
• Do not let the indoor unit get wet. It may cause an
electric shock or a fire.
• Do not use water or air of 50˚C or higher for clean-
ing air filters and outside panels.
HOW TO CLEAN THE SUCTION GRILLE
1. Open the suction grille.
Slide both knobs and then pull them downward.
(Do the same procedure for closing.)
2. Remove the air filter.
Refer to “HOW TO CLEAN THE AIR FILTER”.
(Refer to Fig. 3)
3. Remove the suction grille.
Open the suction grille and pull the clips on the
back of the suction grille forward.
(Refer to Fig. 4)
4. Clean the suction grille.
Wash with a soft bristle
brush and neutral deter-
gent or water, and dry
throughly.
Содержание E Series
Страница 1: ...SiAU18 715 Applied Models Super Multi Plus Cooling Only Super Multi Plus Heat Pump E Series ...
Страница 26: ...SiAU18 715 Specifications 13 Part 2 Specifications 1 Specifications 14 1 1 Cooling Only 14 1 2 Heat Pump 23 ...
Страница 87: ...Refrigerant Flow for Each Operation Mode SiAU18 715 74 Refrigerant Circuit ...
Страница 139: ...Indoor Unit SkyAir Models SiAU18 715 126 Function ...
Страница 177: ...Test Operation and Field Setting for RA Indoor Unit SiAU18 715 164 Test Operation ...
Страница 299: ...Instruction SiAU18 715 286 Operation Manual 2 6 Ceiling Suspended Type ...
Страница 326: ...SiAU18 715 Service Check Function Troubleshooting 313 ...
Страница 423: ...Method of Replacing The Inverter s Power Transistors Modules SiAU18 715 410 Troubleshooting ...
Страница 443: ...Wiring Diagrams SiAU18 715 430 Appendix ...
Страница 449: ...SiAU18 715 vi Index ...