SiAU18-715
Instruction
Operation Manual
275
V. THE UNITS GIVE OFF ODORS
The unit absorbs the smell of rooms, furniture,
cigarettes, etc., and then emits them.
VI.THE LIQUID CRYSTAL OF THE REMOTE CON-
TROLLER SHOW “
”
• It happens immediately after the main power
supply switch is turned on.
This shows that the remote controller is in normal
condition.
This continues temporary.
I. If one of the following malfunctions occurs,
take the measures shown below and contact
your Daikin dealer.
The system must be repaired by a qualified service
person.
WARNING
When the air conditioner is in abnormal con-
ditions (smell of something burning, etc),
turn off power, and contact your dealer
Continued operation under such circumstances
may result in a failure, electric shock, and fire.
•
If a safety device such as a fuse, a breaker, or an
earth leakage breaker frequently actuates, or ON/
OFF switch does not properly work.
Measure: Turn off the main power switch
•
If water leaks from unit.
Measure: Stop the operation.
•
If the display “
” (INSPECTION), “UNIT No.”,
and the OPERATION lamp flash and the “MAL-
FUNCTION CODE” appears.
Measure:
Notify your Daikin dealer and inform
him/her of the display.
10. TROUBLE SHOOTING
OPERATION lamp
INSPECTION
display
MALFUNCTION
CODE
INDOOR UNIT No. in which a
malfunction occurs
II. If the system does not properly operate
except for the above mentioned case, and
none of the above mentioned malfunctions is
evident, investigate the system according to
the following procedures.
1. If the system does not operate at all.
•
Check if there is a power failure.
Wait until power is restored. If power failure
occurs during operation, the system automati-
cally restarts immediately after the power sup-
ply recovers.
•
Check if the fuse has blown or breaker has
worked.
Change the fuse or set the breaker.
2. If the system stops operating after operating
the system.
•
Check if the air inlet or outlet of outdoor or
indoor unit is blocked by obstacles.
Remove the obstacle and make it well-venti-
lated.
•
Check if the air filter is clogged.
Ask a qualified service person to clean the air
filters (Refer to MAINTENANCE).
3. The system operates but it does not suffi-
ciently cool or heat.
•
If the air inlet or outlet of the indoor or the out-
door unit is blocked with obstacles.
Remove the obstacle and make it well-venti-
lated.
•
If the air filter is clogged.
Ask a qualified service person to clean the air
filters (Refer to MAINTENANCE).
•
If the set temperature is not proper (Refer to
ADJUSTMENT).
•
If the FAN SPEED button is set to LOW
SPEED (Refer to ADJUSTMENT).
•
If the air flow angle is not proper
(Refer to AIR FLOW DIRECTION ADJUST).
•
If the doors or the windows are open. Shut
doors or windows to prevent wind from coming
in.
•
If direct sunlight enters the room (when cool-
ing).
Use curtains or blinds.
•
When there are too many inhabitants in the
room (when cooling).
Cooling effect decreases if heat gain of the
room is too large.
•
If the heat source of the room is excessive
(when cooling).
Cooling effect decreases if heat gain of the
room is too large.
3P156215-1
Содержание E Series
Страница 1: ...SiAU18 715 Applied Models Super Multi Plus Cooling Only Super Multi Plus Heat Pump E Series ...
Страница 26: ...SiAU18 715 Specifications 13 Part 2 Specifications 1 Specifications 14 1 1 Cooling Only 14 1 2 Heat Pump 23 ...
Страница 87: ...Refrigerant Flow for Each Operation Mode SiAU18 715 74 Refrigerant Circuit ...
Страница 139: ...Indoor Unit SkyAir Models SiAU18 715 126 Function ...
Страница 177: ...Test Operation and Field Setting for RA Indoor Unit SiAU18 715 164 Test Operation ...
Страница 299: ...Instruction SiAU18 715 286 Operation Manual 2 6 Ceiling Suspended Type ...
Страница 326: ...SiAU18 715 Service Check Function Troubleshooting 313 ...
Страница 423: ...Method of Replacing The Inverter s Power Transistors Modules SiAU18 715 410 Troubleshooting ...
Страница 443: ...Wiring Diagrams SiAU18 715 430 Appendix ...
Страница 449: ...SiAU18 715 vi Index ...