Breadcrumb Field code
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
Setting name
A.8
[9-0E]
0~8,step:1
6
A.8
[A-00]
0
A.8
[A-01]
0
A.8
[A-02]
0
A.8
[A-03]
0
A.8
[A-04]
0
A.8
[B-00]
0
A.8
[B-01]
0
A.8
[B-02]
0
A.8
[B-03]
0
A.8
[B-04]
0
A.8
[C-00]
R/W
0: Solar priority
1: Heat pump priority
A.8
[C-01]
0
A.8
[C-02]
0
A.8
[C-03]
0
A.8
[C-04]
3
A.8
[C-05]
R/W
1: Thermo ON/OFF
2: C/H request
A.8
[C-06]
R/W
0: -
1: Thermo ON/OFF
2: C/H request
A.8
[C-07]
R/W
0: LWT control
1: Ext RT control
2: RT control
A.8
[C-08]
R/W
0: No
1: Outdoor sensor
2: Room sensor
A.8
[C-09]
R/W
0: Normally open
1: Normally closed
A.8
[C-0A]
R/W
0: Disable
1: Enable
A.8
[C-0C]
R/W
0~7
4
A.8
[C-0D]
R/W
0~7
4
A.8
[C-0E]
R/W
0~7
4
A.8
[D-00]
0
A.8
[D-01]
R/W
0: No
1: Open tariff
2: Closed tariff
3: Thermostat
A.8
[D-02]
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
3: Circul. Pump
4: CP & disinf. Sh
A.8
[D-03]
R/W
0: Disabled
1: Enabled, shift 2°C (from -2 to 2°C)
2: Enabled, shift 4°C (from -2 to 2°C)
3: Enabled, shift 2°C (from -4 to 4°C)
4: Enabled, shift 4°C (from -4 to 4°C)
A.8
[D-04]
R/O
0: No
1: Pwr consmp ctrl
A.8
[D-05]
1
A.8
[D-07]
R/W
0: No
1: Yes
A.8
[D-08]
R/O
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.8
[D-09]
0
A.8
[D-0A]
R/O
0: Not present
1: 1 /m³
2: 10 /m³
3: 100 /m³
A.8
[D-0B]
2
A.8
[D-0C]
R/W
0~49
20
A.8
[D-0D]
R/W
0~49
20
A.8
[D-0E]
R/W
0~49
15
A.8
[E-00]
R/O
0~5
3: Hybrid
A.8
[E-01]
R/O
0: 08
A.8
[E-02]
R/O
1: Type 2
A.8
[E-03]
0
A.8
[E-04]
R/O
0
A.8
[E-05]
R/W
0: No
1: Yes
A.8
[E-06]
R/W
0: No
1: Yes
A.8
[E-07]
R/W
0~6
4: Type 5
6: Type 7
A.8
[E-08]
0
A.8
[E-09]
0
A.8
[E-0A]
0
A.8
[E-0B]
0
A.8
[E-0C]
0
A.8
[F-00]
0
A.8
[F-02]
3
A.8
[F-03]
5
A.8
[F-04]
0
A.8
[F-05]
0
A.8
[F-06]
0
A.8
[F-09]
0
A.8
[F-0A]
0
--
--
--
--
--
--
--
--
--
--
--
Domestic heating water priority.
--
--
--
--
What is the thermo request contact type for the main zone?
What is the thermo request contact type for the add. zone?
What is the unit control method in space operation?
Which type of external sensor is installed?
What is the required alarm output contact type?
Indoor quick heat-up function
High electricity price decimal (Do not use)
Medium electricity price decimal (Do not use)
Low electricity price decimal (Do not use)
--
Forced off contact
Which type of DHW pump is installed?
Leaving water temperature compensation around 0°C.
Is a demand PCB connected?
--
Is a solar kit connected?
Is an external kWh meter used for power measurement?
--
--
Is a DHW tank installed in the system?
Can the system prepare domestic hot water?
--
Is an external gas meter used for power measurement?
--
What is the high electricity price (Do not use)
What is the medium electricity price (Do not use)
What is the low electricity price (Do not use)
What kind of DHW tank is installed?
--
--
What is the indoor unit software type?
--
--
--
--
--
Which type of unit is installed?
Which type of compressor is installed?
--
--
--
--
--
--
4P471775-1B - 2021.02
CHYHBH*