8
|
Configuration
Installer reference guide
131
C08AF + EHYKOMB33A
Daikin Altherma R Hybrid
4P471761-1E – 2020.10
CAUTION
The disinfection function settings MUST be configured by the installer according to
the applicable legislation.
CAUTION
Make sure to activate the disinfection function when a third-party tank is installed.
#
Code
Description
[A.4.4.2]
[2‑00]
Operation day
:
▪
0:
Each day
▪
1:
Monday
▪
2:
Tuesday
▪
3:
Wednesday
▪
4:
Thursday
▪
5:
Friday
(default)
▪
6:
Saturday
▪
7:
Sunday
[A.4.4.1]
[2‑01]
Disinfection
▪
0:
No
(default)
▪
1:
Yes
[A.4.4.3]
[2‑02]
Start time
: 00~23:00, step: 1:00 (default:
23:00).
[A.4.4.4]
[2‑03]
Temperature target
: fixed value (default:
60°C)
[A.4.4.5]
[2‑04]
Duration
Range 40~60 minutes (default: 40 minutes)
00.00
22.00
24.00
01.00
23.00
t
T
DHW
T
H
T
U
[2-02]
[2-03]
[2-04]
T
DHW
Domestic hot water temperature
T
U
User set point temperature
T
H
High set point temperature [2-03]
t
Time