Description
N/A
[9‑0D]
Pump speed limitation
▪
0: No limitation.
▪
1~4: General limitation. There is limitation in all
conditions. The required delta T control and
comfort are
NOT
guaranteed.
▪
5~8 (default: 6): Limitation when no actuators.
When there is no heating/cooling output, the
pump speed limitation is applicable. When
there is heating/cooling output, the pump
speed is only determined by delta T in relation
to the required capacity. With this limitation
range, delta T is possible and the comfort is
guaranteed.
The maximum values depend on the unit type:
[9-0D]=0
[9-0D]=5
a (kPa)
b (l/min)
a (kPa)
b (l/min)
a (kPa)
b (l/min)
a (kPa)
b (l/min)
[9-0D]=6
[9-0D]=7
[9-0D]=8
a (kPa)
b (l/min)
a
External static pressure
b
Water flow rate