Error code
Detailed error code Description
7H
04
The water flow problems mainly
occurred during domestic hot water
operation. Check the domestic hot
water circuit.
7H
05
The water flow problems mainly
occurred during space heating
operation. Check the space heating
circuit.
7H
06
The water flow problems mainly
occurred during cooling/defrost
operation. Check the space heating/
cooling circuit.
Additionally, this error code might be an
indication of frost damage to the plate
heat exchanger. In that case, contact
your local dealer.
INFORMATION
Error AJ-03 is reset automatically from the moment there is a normal tank heat-up.
INFORMATION
Error EC-04 is reset automatically from the moment the domestic hot water tank is
preheated to a sufficiently high temperature.
INFORMATION
If a U6‑36 error occurs, press the gas boiler’s On/off button.
INFORMATION
If a U4‑00 error occurs, the indoor unit cannot communicate with the outdoor unit.
When the plate heat exchanger of the indoor unit is freezing, the pump of the indoor
unit will be forced ON to prevent freeze-up.
Error codes of the gas boiler
The controller on the gas boiler detects faults and indicates them on the display by
error codes.
If the LED is flashing, the controller has detected a problem. Once the problem is
rectified, the controller can be restarted by pressing the button.
Following table shows a list of error codes and the possible solutions.
Error code Cause
Possible solution
10, 11, 12,
13, 14
Sensor fault S1
▪
Check wiring
▪
Replace S1