background image

 

 
 
 

Vacuum Pump 
Models QV2 & QV5 

 

Operation and Maintenance 
Instruction Manual 2002-0010 

 

Rev. 6 – January 2011 

 

 

 

 

 
 

 

 

 

Product Leadership   •   Training   •   Service   •   Reliability

 

Содержание QV2

Страница 1: ...Vacuum Pump Models QV2 QV5 Operation and Maintenance Instruction Manual 2002 0010 Rev 6 January 2011 Product Leadership Training Service Reliability...

Страница 2: ...G WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND II ANY OBLIGATION LIABILITY RIGHT CLAIM OR REMEDY IN CONTRACT OR TORT WHETHER OR NOT ARISING FRO...

Страница 3: ...iii Contents Introduction 1 Features 1 Oil Pre Fill Notice 1 Technical Characteristics 2 Pump Components 2 Operation 3 Gas Ballast Operation 4 Warnings Cautions 5 Warnings 5 Cautions 5 Troubleshooting...

Страница 4: ...Vacuum Pump Models QV2 QV5 iv P N 2002 0010 Rev 6...

Страница 5: ...gh rate of heat dissipation which provides for continuous pump operation Two stage design The second stage of the two stage design starts pumping at a lower pressure to pull a deeper ultimate vacuum H...

Страница 6: ...Motor 1 4 HP 1 2 HP Intake Fitting 1 4 3 8 1 2 Flare 1 4 3 8 1 2 Flare Motor Speed 1 720 rpm 3 450 rpm Oil Capacity 11 8 fl oz 350 ml 14 2 fl oz 420 ml 13 0 5 3 10 0 in 330 135 255 mm 13 8 5 6 10 4 in...

Страница 7: ...ntake fitting cap and connect the pump to the system being evacuated using a hose with appropriate fittings Keep the connection as short as possible and ensure that all connections are sealed and not...

Страница 8: ...s reached its operating temperature This is done to ensure that vapor does not condense inside of the pump NOTE The gas ballast should be closed and the intake valve should be open during typical oper...

Страница 9: ...air being evacuated contains dust or is above 175 F 80 C then a filter or cooling device should be installed at the pump s intake Do not operate the pump for more than 3 minutes with the intake open t...

Страница 10: ...rain oil until level is correct as viewed through sight glass Oil injection Pump is too small Check the size of the system being evacuated and choose proper pump size Oil temperature is too low Open i...

Страница 11: ...he intake and exhaust caps and place the pump in a dry location Only qualified technicians should attempt to disassemble and repair the vacuum pump Service performed by unauthorized personnel during t...

Страница 12: ...QV2 QV5 Headquarters 621 Hunt Valley Circle New Kensington PA 15068 Ph 724 334 5000 Fax 724 334 5001 Toll Free 800 736 4666 Website www mybacharach com E mail help mybacharach com Printed in U S A 8 P...